No draft in the chimney stove: what to do, possible causes and solutions

  • Reason #2 – poor ventilation
  • Reason #3 – external factors
  • Reason #4 – fuel
  • Reason #5 – the presence of a canopy on the chimney
  • How to solve the problem of lack of traction
      Try cleaning the chimney
  • If cleaning doesn't help
  • Stabilizing devices
  • Deflectors
  • Rotary turbines
  • Revision of the ventilation system
  • Conclusion
  • Let's take a closer look at why there is no draft in the stove or chimney of a private house or bathhouse, and what to do. Let's find out how to determine the presence of this problem and what to do to fix it.

    Draft is the force of movement of exhaust gases along the outlet channel, appearing due to the difference in air temperatures. If it is normal, combustion products freely go outside; if there is not enough of it (or it is completely absent), gases accumulate in the pipe and either clog the hose, gradually reducing its throughput, or flow back into the room. This is dangerous because the smoke contains harmful substances that can cause poisoning.

    The following signs will alert you to problems:

    • the appearance of smoke when opening the cleaning door;
    • smoke from pipes;
    • pops of smoke masses on the stove door.

    How to check the draft in the furnace and understand whether it is there or not

    The sooner you notice the problem, the easier it will be to get rid of it. Therefore, inspect your heating system regularly. Among the obvious manifestations:

    • puffs of smoke appearing immediately as soon as you open the firebox door;
    • white, gray or even black smoke masses ooze from cracks or pipe joints.

    When at least one of these phenomena is observed, it is time to sound the alarm. But even if they are not there, this does not mean that combustion products normally come out and do not stagnate in the outlet channel.

    If there are no external signs, but there are suspicions, the lack of traction can be checked in the following simple ways:

    • Using a candle, light it, carefully insert it into the firebox and look at the flame. If the light “goes” away from you, even further inward, then the situation is normal; if the tongue remains in place and does not even tremble, the air masses are not circulating properly.
    • Using a ribbon or piece of paper, take it by the edge and bring it to the pipe. If the free end pulls into the sleeve, then everything is fine, if it does not move, the hood does not work.
    • Using a mirror, you need to carefully bring it closer to the fuel-burning chamber and take a closer look. If moisture appears on its surface, there is a problem with the removal of combustion products.
    • Look at the color of the flame: when it is yellowish-golden, everything is good, if it is bright orange or, even more so, red, there is poor air circulation.

    After you have checked the lack of traction, you need to find out the reasons for its occurrence.

    Conclusion

    The main thing in the design of a stove is the correct calculation of the parameters of the firebox and chimney. Seek help from specialists. Laying stoves is a very difficult task; it is no coincidence that the skill of a stove maker has been highly valued at all times. The second aspect of this problem is to use only high-quality materials that can withstand high temperatures and do not collapse.

    Periodic maintenance of the chimney and firebox will not only eliminate draft problems, but also ensure fire safety. Monitor weather changes, use all stove settings correctly, and use high-quality fuel. If these simple conditions are met, your home will always be warm and cozy.

    Why there is no draft in the chimney: reasons for its absence

    There are two fundamentally different situations:

    • there was no normal traction initially;
    • over time, the traction force weakened, and then completely disappeared (or is insufficient).

    The reasons for their occurrence are associated with a number of factors, which we analyzed and combined into key groups - according to the nature, degree, and consequences of their impact. Next, we will look at the most important points and find out how to prevent each of them or eliminate their consequences.

    Reason #1 – chimney design

    • There were errors in the configuration.
    • The pipe diameter is smaller than that required for the stove of the selected power and recommended by the heating unit manufacturer.
    • When laying the channel, turns of 90° were made, while the maximum possible value (according to SNiP) is only 45°. Ideally, the chimney should be vertical throughout. But sometimes this can be difficult or impossible to achieve. In this case, tees and transitions (elbows) are used. If your channel has at least one transition at 90°, then you need to extend the pipe by 1 m, if there are two transitions (two angles), then by 2 m. If you used a transition at 45°, then two such angles - this is plus 1 m in height.
    • Horizontal sections along the sleeve are either too common or too long - their total length should not exceed a distance of 1 m.
    • A non-cylindrical or round pipe shape was chosen - weak draft in a chimney with a square cross-section occurs more often due to turbulence that forms in the corners and interferes with the exit of combustion products. As a rule, square sections have brick structures. You can select the appropriate option in the catalog.

    Our production

    Single wall chimneys

    Double wall chimneys

    Mounting elements

    If your chimney is brick and not lined, be sure to line it with stainless steel pipes. These pipes are easy to install, have sealed joints and a smooth inner surface, on which the likelihood of soot accumulation is minimal.

    • The vent is too short - there is no flow of fresh air.
    • During lining, pipes of different diameters were taken, as a result, large quantities of soot accumulate at their joints, making it difficult to remove gas masses.
    • The joints between the pipes are not airtight and there are gaps.
    • There is no cap (umbrella, head) that protects against the ingress of foreign objects and precipitation.

    Incorrect assembly

    It is necessary that the pipe protrudes above the level of the flat roof by at least half a meter. The location of it is also important. If the distance to the ridge is less than 1.5 m, the channel needs to be increased by another 0.5 m. The total length of the hose, starting from the boiler, must be more than 5 m, but at the same time be within the building codes and comply with the recommendations drawn up by the heating equipment manufacturer.

    The chimney is not properly insulated

    If this is not done, the exhaust gases will cool before they escape and settle on the walls of the pipe in the form of condensate.

    Therefore, in areas of low temperatures (attic, cold shop, street) it is necessary to install insulated sandwich chimneys made of stainless steel. Then the temperature of the exhaust gases will be higher than the dew point, and the likelihood of condensation will be less.

    What else affects the amount of thrust?

    First of all, the height of the chimney. The minimum required height is 5 meters. This is enough for a natural vacuum to occur and the upward movement to begin. The higher the chimney, the stronger the draft. However, in a brick chimney with an average cross-section of 140x140mm, at a height of over 10-12 meters, the draft no longer increases. This is because the wall roughness value increases with increasing height. Therefore, excess height does not affect traction. A similar question arises among those who want to use ducts for chimneys in their homes. They come in large heights and narrow cross-sections, so a serious fireplace is rarely connected to such a chimney.

    Reasons affecting cravings:

    • Flue gas temperature. The higher the temperature, the faster the flue gases rush upward, creating a greater draft.
    • Chimney heating. The faster the chimney warms up, the faster the poor draft normalizes.
    • The degree of roughness of the chimney and internal walls. Rough walls reduce traction, while smooth walls have better traction.
    • The cross-sectional shape of the chimney. The circular section is a sample; oval, rectangular and so on. The more intricate the shape, the more strongly it affects traction, reducing it.
    • It is important to note that the ratio of the size of the firebox, the diameter of the outlet pipe and the diameter of the chimney pipe also influences. If the height of the designed chimney is excessive, you should consider reducing the cross-section of the chimney by an average of 10%. Install an adapter on the firebox, on the smoke pipe (for example, from a 200-diameter to a 180-diameter) and take the 180-diameter pipe itself. This is allowed by the manufacturers. If we talk about “EdilKamin” as an example, you can see that in the instructions for the fireboxes he describes what diameter the chimney should be depending on the height.

    For example:

    • height up to 3 m – diameter 250,
    • height from 3 m to 5 m – 200,
    • height from 5 m and above – 180 or 160. Strict recommendations.

    Other manufacturers (such as Supra) admit that changes are possible. Some don't allow it at all. Therefore, following the instructions, you should not forget about the processes occurring in the chimney.

    Reason #2 – poor ventilation

    Incorrect air exchange, in one of the rooms or in the entire building, is also a factor explaining why there is no draft in the stove of a house or bathhouse. Combustion products are not removed properly and/or in full if:

    • In the boiler room/room, windows are constantly or often open, which are also installed at a level significantly higher than the firebox door.
    • There are strong drafts that disrupt the usual movement of gas masses through the rooms.
    • There is no flow of fresh air, and the sleeve seems to “suck” it from the street so that a vacuum is not created.

    The difficulty and even danger here is that these shortcomings may not manifest themselves for a long time, and then lead to the release of exhaust gas, and this is fraught with carbon monoxide poisoning.

    The role of the damper in the operation of the heating system

    The damper, or chimney damper, protects the house from fire and prevents the possibility of reverse draft.

    It is mounted:

    • in the door of the stove (fireplace) or located in the stove (fireplace) itself;
    • directly into the chimney pipe.

    The chimney damper acts as a chimney draft regulator. By closing the damper, we reduce the cross-sectional area of ​​the chimney, and accordingly, the draft decreases. We open the damper, the cross-section increases, and so does the chimney draft.

    After the fuel has burned out in the heating device, you can close the damper, thereby reducing heat losses. The stove or fireplace will not cool down as quickly, which will save on fuel.

    Reason #3 – external factors

    First of all, these are atmospheric phenomena. Precipitation in the form of prolonged rains and snowfalls, fogs with increased humidity levels, squally or simply sharp winds - all this creates a pressure difference. As a result, when leaving outside, combustion products encounter strong air resistance, return back and enter the room. Their accumulation results in the deposition of soot and condensate on the walls of the hose, which means a decrease in its cross-section (throughput), up to complete clogging.

    If you have poor draft in the chimney, the reasons may be the following, for example:

    • a tall tree grows next to a house or bathhouse, the branches of which cover the chimney;
    • in the immediate vicinity of your building some new structure has appeared; it is higher than yours and becomes a “wind support”, that is, it reflects the combustion products coming from you;
    • When there is high humidity or frost, the air becomes heavier, falls down and presses inside the pipe.

    It is clear that not every such factor can be eliminated with equal ease. If you can trim the same branches without difficulty, then how can you negotiate with the person living nearby? You will have to use special elements like deflectors or rotary turbines, which we will discuss in detail below.

    How to solve the problem of lack of traction

    First of all, it is important to determine what exactly the reason is and what its nature is. If there is no normal air exchange at all and the problem is an incorrectly laid out smoke duct, you need to make structural changes:

    • Increase the section of the hose - expand it to the level of the firebox pipe, this will increase the activity of circulation of gas masses.
    • Extend the pipe - make it rise above the roof (ridge) by at least 0.5 m, and if there are trees or other buildings in the immediate vicinity of the building, then it is better by 1.5 m.
    • Simplify the chimney - replace its horizontal sections with inclined ones, remove straight turns (remember, a change in direction is allowed by no more than 45 degrees).

    But if this is not the case, and there is no draft in the heating boiler, what should you do then? Most likely, the lack of traction is due to errors made when installing the heating unit. In such a situation, it is necessary to identify and eliminate the defect, and then recheck the quality of air exchange.

    If combustion products were initially discharged normally, but over time they began to accumulate in the channel, most likely something is simply clogging the sleeve, and this obstacle will have to be removed.

    Try cleaning the chimney

    This can be done both “the old fashioned way,” that is, mechanically, and with the help of chemical means.

    • Buy a long brush from a specialized store or design one yourself (for this you only need a rag and a strong metal cord). Take this tool and run it along the walls of the pipe. This way, you will remove soot, condensation, frozen moisture and even debris that has accumulated inside.
    • Or add a composition to the firebox that will mix with the combustion products and, when the gas escapes, take soot and liquid with it. Naturally, it is important that it is a non-toxic product. Consider the option of natural remedies, for example, when lighting with wood, it may well be the rock salt that everyone is familiar with. Or you can purchase ready-made chimney cleaning products, which are available in a wide range on the market.

    So that a few years after installing the heat generator you don’t have to wonder why there is no draft in the stove at home, do not let it clog. Use a brush or chemical at least once or twice every six months - remember, regular prevention is important and often saves you from air exchange problems.

    If cleaning doesn't help

    If the issue is not soot or debris, or errors in installing the heat generator and smoke duct, then what is it? This means that the problem is in an external factor - in wind pressure from a tree or a nearby building, in heavy gusts of air currents.

    Is there a solution to this situation? Yes, this is the installation of one of the auxiliary elements. Below we will look at each one that deserves attention.

    Stabilizing devices

    The reason why there is no draft in the stove in a bathhouse or in a house may be that the exhaust gases heat up the hose too much, does not create the necessary difference in atmospheres, and as a result does not have time to escape completely, but accumulates near the walls of the channel.

    If this is the case, a regulator should be hung at the end of the pipe - a device equipped with a temperature sensor. It works clearly and quite reliably:

    • triggers when the temperature rises (which is observed when gas accumulates) and opens the fuse valve;
    • Fresh air enters the chimney from the street.

    As a result, the pressure difference stabilizes - hence the name of the device, which, by the way, operates in automatic mode.

    Deflectors

    If there is no draft in the furnace, and the reason is wind pressure, the solution to the problem is to install one of these devices. Already from the name it is clear what it does - it deflects air masses reflected by high interference (the wall of a neighboring house, a trunk or branch of a tree). This is a kind of outlet, thanks to which exhaust gases are completely removed to the outside. Most often, such an element reduces pressure and improves the aerodynamic effect of the emission of combustion products. It is useful even during heavy gusts, which is why it is appreciated.

    The high popularity explains the variety of models, among which deflectors-vanes stand out - a kind of hybrid that takes the best from both devices. Thanks to the presence of the upper glass, it perfectly captures the direction of wind flows, and due to the cap it is well protected from precipitation and mechanical debris.

    Ferrum's product range includes an umbrella with wind protection, which is easily and tightly inserted into the chimney without the use of self-tapping screws. The price list can be found on the website.

    Rotary turbines

    If all the reasons for the lack of draft are eliminated or corrected, there is no draft in the furnace anyway, what to do in such a situation? Place this final element - a rotary turbine - at the outlet of the channel: it will forcefully push out the waste combustion products when necessary.

    A screw on an electric drive is responsible for removing the gas, the timely activation of which is carried out by the activation of temperature and air speed sensors. The design of the device is modern and at the same time simple and reliable, which is why rotary turbines are popular.

    Revision of the ventilation system

    It is necessary to reconsider its organization, think about how to correct the shortcomings, in particular, remove drafts. This is relevant when you have gone through all the options, found out that the problem is not in external factors and not in the chimney, but you still don’t understand why there is no draft in the boiler. All you need is:

    • frequently ventilate the rooms, and especially the one where the heating unit is located;
    • install supply valves on the windows so that they provide fresh air in portions;
    • use devices that will forcefully ventilate rooms;
    • and all this should be combined with competent prevention - not only with cleaning the pipes, but also with heating the entire system. It is also necessary to carefully monitor the performance of all devices such as rotary turbines or deflectors.