Here you will learn:
- Features of Galan boilers
- Operating principle of the Galan electrode boiler
- Main models of Galan boilers
- Electrode boilers Galan - user reviews
Electric heating equipment is used to create heating systems in buildings not connected to gas mains. It cannot be said that this is the cheapest heating method, but sometimes it is the only acceptable one. In order to make heating more economical, it is necessary to purchase a Galan electrode boiler, the operating principle of which is to heat the coolant without heating elements.
In this review we will look at:
- Principles of ion heating in Galan heating boilers;
- Popular boiler models;
- User reviews.
After reading the material, you will be able to make your choice and decide whether you need electrode boilers or not.
Coolant and inhibitor (2)
- The most important advantage No. 1: The ability to significantly (from 40%) save on monthly electricity bills for electric heating when using the Galan electrode boiler, in contrast to the heating costs of any other type of electric boiler.
- The most important advantage No. 2: The ability to heat a larger volume of a room with less power if you are limited in input power per room.
- The most important advantage No. 3: The cost of the electrode / block of electrodes is lower than the cost of heating elements / block of heating elements of similar power. Taking into account the significantly lower operating costs (monthly payment for electricity), the total cost of ownership of the Galan electrode boiler is significantly lower than the cost of ownership of any heating element boiler from any manufacturer.
Features of Galan boilers
Main characteristics of Galan electrical equipment:
- high level of quality;
- compact dimensions;
- reliability.
Device
Elements of Galan heating equipment are:
- working chamber;
- electrodes;
- sealant and insulation of electrodes;
- power supply terminals.
Principle of operation
The operating principle of the Galan heating system does not differ from the traditional one. The water heated in the generator passes through the main piping. Entering the radiator, it gives off its heat as much as possible, due to this the air in the room heats up.
The housing acts as the first electrode, which must be grounded, and the other electrode, connected to the phase, is located inside the system and is isolated from the housing.
Specially prepared water having certain resistivity parameters can be used as a coolant, but it is best to use a special Argus-Galan liquid. This way the unit will last much longer.
Galan electric units can be used not only to heat a room, but also to provide hot water supply. Many Galan models (Geyser, Hearth, Vulcan, TEN Series) are supplemented with external storage boilers, due to which the water is heated by coolant from the main source.
Specifications
Galan equipment is constantly being modernized and improved as a result of changes in production technology. The electric boilers produced by the Galan company for heating premises correspond to their main purpose, have dimensions convenient for installation, and are made of materials that have high corrosion resistance, environmental friendliness and safety. You can buy a Galant boiler at a price that directly depends on the power and configuration of the product.
Technical characteristics of Galan electrode heating systems:
- voltage – 220/380 v, 50 Hz;
- heated room area in the range from 20 to 250 m2;
- power range of models from 2 to 25 kW;
- current range for models is from 9.2 to 37 A;
- recommended coolant is Argus-Galan liquid;
- water as a coolant – resistivity (3 kOhm/cm2—32 kOhm/cm2) at 150 degrees.
Advantages
Galan heating equipment has a number of advantages over heating element analogues.
The main advantages of Galan boilers:
- They do not require additional installation costs, except for the purchase of a heat source. Installing the device is much cheaper than installing equipment that runs on liquid fuel. There is no need to build a chimney.
- Does not require routine maintenance or cleaning.
- Made from environmentally friendly and safe material.
- They have a small weight and dimensions, as a result of which you can save space; the unit does not require a separate room.
- Easy to install, you can install it yourself;
- Fireproof.
- operate from an electrical network of any voltage.
- Wide range of power. You can choose a unit that can heat a room of about 20 square meters. m. or a whole house of 250 sq. m. m. When combining devices into a system, it is possible to heat a room measuring more than a thousand square meters.
- The operation process is automated; the devices are equipped with a control unit.
- Low noise level during operation.
- Availability of protective systems.
- Efficiency.
- Possibility of programming operating modes.
Flaws
The disadvantages of heating units include:
- Inability to use for floor heating, swimming pool heating, or greenhouse premises.
- Installation of electrical equipment with a power of more than 10 kW requires approval from Energonadzor.
- For normal operation, you will need an additional device for water circulation (pump), since in its absence the water may boil.
- The high cost of consumed electricity, but this is rather a disadvantage of a different nature.
- The need to monitor the condition of the electrodes, because they tend to be destroyed by water.
- Ability to operate only on electricity.
Electrode boiler GALAX 15 N
2,015.00Br Add to cart
The head of state signed a Decree that should stimulate the consumption of electrical energy in Belarus. From January 1, 2022, it will become 3 times cheaper for heating and hot water supply needs. As the press service of the Ministry of Antimonopoly Regulation and Trade reported, Decree No. 492 “On setting tariffs for housing and communal services for the population for 2022” comes into force on January 1, 2022. Part of the provisions of the decree concerns an increase in tariffs for basic housing and communal services for the population, and the other concerns a reduction. Thus, tariffs for electricity and gas for food preparation purposes were increased by 21.8% and 25.6%, respectively, which ensures a 100 percent reimbursement level for these services. But the tariff for electrical energy for heating and hot water supply has been reduced three times in order to stimulate electricity consumption in the republic.
From January 1, 2022, the cost of electricity for heating and hot water supply for houses that are not connected to central heating and gas supply is set at 0.0335 rubles per 1 kWh. Heating appliances will need to be equipped with a separate meter.
Installation and connection, nuances
Compact design and low weight of the unit create optimal conditions for easy installation.
What kind of coolant can I use?
Kinds:
- Water, distilled water is the best option.
- Boiled water with the addition of Galan inhibitor.
- Special liquid "Argus-Galan", developed specifically for use in "Galan" heating systems.
Sensor placement rules
A mandatory requirement is to ensure that the sensors are positioned correctly:
- The inlet temperature sensor is installed on the outlet pipe of the very last section of the radiator.
- The sensor for measuring the output temperature parameter at the outlet is installed on the outlet pipeline of the boiler.
- To connect the sensors, stranded copper wire is used. Its cross-section should be in the range from 0.5 to 1 mm2.
- 25 A circuit breaker for overload protection.
- The button to turn off/on the thermal relay must be in the recessed position.
Connection diagrams
When connecting Ochag-Turbo boilers to the power supply, the protective casing is not removed. The power supply is connected to the wires removed from the casing. The Navigator electronic regulator can install electrical equipment in accordance with the diagrams.
Fundamental
Parallel
Purchase and delivery
We sell heating devices from trusted brands, as well as Russian cast iron radiators, underfloor heating systems, pipes and fittings. Cash and non-cash payments are accepted, there are discounts for large orders and for regular clients. Delivery of orders throughout Moscow and the region is carried out in the shortest possible time. For additional consultations, assistance in choosing heating equipment and system components, as well as for direct ordering, please contact the company’s managers. The website contains contact phone numbers; you can use the call back option, as well as write to managers using the feedback form.
About installation in detail
Today there are four types of connections that are actively used:
- parallel;
- standard;
- floor heating;
- modular.
The most popular are parallel and standard connections. Let's look at how to connect the boiler this way.
The first step is to decide on a suitable location. Next, using a comb, we connect the main device, which is necessary to distribute water or antifreeze through the radiators. The latter have special taps that can be used to regulate the amount of coolant passing through.
Please note that the Galan boiler diagram of any model involves the installation of a system for bleeding excess air from the system. This will help keep the equipment in good condition and prevent its premature breakdown. At the final stage, the boiler will be connected to the network.
Do you want to connect the boiler to the underfloor heating system? Do the following. Connect air exhaust devices to the heated floor. Install sensors that monitor temperature and pressure. Then install the controllers in the niche and connect the device to the network. Remember that you need to carry out installation only when you have experience in carrying out such work; in other cases, it is better to involve specialists, since you are dealing with electricity. Failure to follow basic safety rules can result in injury and even death due to electrical shock.
DIY installation
Preparation
Algorithm of actions:
- Ground.
- Protect terminals and live parts from moisture and contact with the surfaces of the unit.
- Install a circuit breaker - a switch to cut off the current. A 25 A automatic machine, for example.
- Follow the connection diagram recommended in the data sheet.
- Observe the connection rule: phase - zero - ground.
- Check the tightness of threaded and welded connections.
- Minimize, it is better to prevent the possibility of water getting on the body of the ion boiler.
- Buy an expansion tank.
- Turn off the boiler if ice forms in the heating system and defrost.
- Ensure the cleanliness of the pipeline and prevent the penetration of metal shavings and foreign substances into the device and system.
Installation
Sequence of work:
- Connect the coarse filter.
- After installation, rinse the system thoroughly with Galan inhibitor.
- Install the equipment in a vertical position, with the protective cap at the bottom.
- Secure the equipment to one of the walls of the room. The connection to the heating system is not decisive.
- The unit must be connected to the electrical network by an electrician who has permission to work with electrical equipment up to 1 kW.
- Thoroughly strip the ends of the wire of insulation.
Setting the temperature value
Procedure:
- Set the coolant outlet temperature within 70-75 ºC.
- The input temperature is calculated based on numerous factors: the volume of the heating system, the temperature of the surrounding atmospheric or air space inside the room, the condition and indicator of the thermal insulation protection of the room, the volume of space. On average, this temperature ranges from 40 to 45 ºC.
If the unit is connected correctly, the current parameter reading will be within 23 A. The equipment operates in “automatic” mode during operation. Read sewn in our article.
We prepare water for the coolant
If you still decide to give preference to water, then it is worth preparing it. Tap water is not suitable for electrode devices, only distilled water. To measure resistance, you should take an ammeter.
Adjustment of water conductivity begins as follows. Turn on the unit and after half a minute at a “return” temperature of 15-20 ° C, measure the starting current with an ammeter or current clamp. The unit is turned off. Several situations are possible: the starting current is less than, greater than, or equal to the table value.
Water conductivity correction table | ||||||
No. | Boiler brand | power, kWt | Voltage, V | Phase, F | Starting current of the boiler at a return temperature of 15 °C, A | Maximum current in steady state, at a return temperature of 60 °C, A |
1 | Ochag-2 | 2 | 220 | 1F | 4 | 9,1 |
2 | Ochag-3 | 3 | 220 | 1F | 5 | 13,7 |
3 | Ochag-5 | 5 | 220 | 1F | 10-12 | 22,7 |
4 | Ochag-6 | 6 | 220 | 1F | 15-18 | 27,3 |
5 | Geyser-9 | 9 | 380 | 3F | 6-8 A per phase | 13.7 A per phase |
6 | Geyser-15 | 15 | 380 | 3F | 8-10 A per phase | 22.7 A per phase |
7 | Vulcan-25 | 25 | 380 | 3F | 12-15 A per phase | 37.9 A per phase |
8 | Vulkan-36 | 36 | 380 | 3F | 18-24 A per phase | 54.6 A per phase |
9 | Vulcan-50 | 50 | 380 | 3F | 24-30 A per phase | 75.8 A per phase |
When starting, the starting current is measured with an ammeter, the readings are checked against the table (it is in the installation and operation manual).
When the results are not as desired, and the current is less than the calculated one, add a salt-containing solution - one teaspoon of salt per hundred liters in one step.
When the calculated values are higher than normal, use only pure distilled water, this will correct its resistivity. This is an important indicator for the quality operation of the electrodes.