Separator for removing air from the heating system

Air pockets, microscopic bubbles and various contaminants can significantly disrupt the functioning of the heating system and also reduce its efficiency. The air and sludge separator allows you to eliminate all of the above factors that complicate the operation of the heating system.

Separator of microbubbles and sludge Flamcovent Clean 22 mm - 2" (Netherlands).

The presence of air and air pockets in the heating system creates the following problems for the operation of its elements:

  • Reduced heat transfer from heating devices;
  • Premature wear of circulation pump parts (bearings, blades), as well as a decrease in its operating efficiency;
  • The internal surfaces of radiators, pipes and heating boilers are subject to accelerated corrosion.

The only device that can completely solve the problem of air jams is an air separator.

Flamcovent 3/4″ model without sludge trap. Cost about 2,000 rubles.

A coolant based on ordinary tap water contains a large amount of dissolved air, which, when heated, is released and turns into many small bubbles. The largest number of bubbles is formed in the place where the coolant is heated, i.e. in the heating boiler. After this, the bubbles spread along the heating circuit, where they dissolve in the coolant as it cools.

By installing an air and sludge separator in the supply, immediately after the boiler, bubbles formed in the boiler can be removed. Thus, the coolant entering the heating circuit becomes completely free of oxygen.

In addition, the deaerated coolant will absorb oxygen in those parts of the heating system where it is present. For example, if the walls of polymer pipes do not have an anti-diffusion coating, they will in any case allow oxygen into the system in small quantities. This oxygen is absorbed by the deaerated coolant and delivered to the separator, where it is removed. In this way, the heating system can be completely ventilated.

The disadvantages of the air separator include the fact that, by creating resistance to the flow of coolant, it affects the hydraulics of the entire heating system.

Introduction

It is known that when starting heating systems, big problems are caused by air cavities remaining inside and solid particles or sludge circulating in the flow.
The presence of air cavities and plugs automatically means a high concentration of dissolved gases in the water, which can cause increased corrosion and erosion processes, problems with cavitation, and a decrease in the efficiency of pumps, fittings and heat exchangers. The presence of gases, in turn, stimulates the appearance of solid particles in the coolant. By settling in places with the lowest speed, layers of particles sharply reduce the efficiency of heat transfer. Once they get into pumps and control valves, they quickly damage the equipment. Corrosion processes under a layer of deposited sludge are difficult to slow down. Considering that when systems are periodically stopped for maintenance, tons of particles settle at the bottom of pipelines, this process each time creates new sources of pitting corrosion. Currently existing methods and equipment are aimed largely at treating water entering the system /1/

At the same time, it is sometimes not taken into account that systems cannot be perfectly sealed, gas flows into systems can be quite large even in closed systems, and degassing of large and complex systems can take a long time. In this case, as in the case of start-up, problems can arise even if the quality of the make-up water is normal.

It can also be noted that in case of design or configuration errors, areas of negative pressure may appear in some areas of the systems. In this case, conditions are created for the emergence of stable gas flows into the system.

It is generally accepted that in most cases, installing a sufficient number of air vents will ensure degassing of systems during operation. To evaluate the effectiveness of their use, we recall that the gases in the system are in three states: in the form of cavities, bubbles and microbubbles, and in a dissolved state /2/. The work of air vents is mainly related to the first form, because Only the appearance of a significant volume of gas in the upper part of the air vent activates the mechanism for its removal. The bulk of bubbles and microbubbles moving in the flow simply do not have time to rise into the air vent chamber. Therefore, air vents should be located at the highest points of the system, in places of local elevations and on radiators. In complex systems it is necessary to install a large number of these devices. At the same time, the air vent, along with the expansion tank, is one of the most vulnerable elements. Almost all differences in designs and prices are associated with varying degrees of reliability and protection of air vents from blocking them with bubbles or depressurization when dirt particles get inside the trigger mechanism.

In complex systems with a large number of air vents installed in hard-to-reach places, it is difficult to check the quality of their work. The low price (and sometimes quality) of air vents often does not compensate for the complexity of maintenance and losses from problems that arise. Air cavities that are not removed in time can be reabsorbed by water when the operating mode of the system changes, further stimulating corrosion. Water leaking out or air getting inside when the air vent is depressurized can quickly damage any system. Automatic float air vents remove air pockets and bubbles as they appear in automatic mode /3/. Air vents of this type provide better tightness and are better protected from blocking and depressurization when dirt gets into them.

Mud collectors installed inside the system circuit are usually equipped with mesh with large cells. Otherwise, they quickly become clogged and the circulation flow can be completely blocked. Thus, we can assume that inside the system, as a rule, there are no devices that perform processes of fine cleaning of the coolant from sludge and its amount can increase as a result of chemical reactions or detachment of deposits.

Installation of safety valves

Where are automatic and manual air vents installed? All radiators have appropriate places for installing such products, and it does not matter what type they are: manual or automatic. Manual products are installed one unit per radiator. They are usually located at the top point of the battery, distant from the supply pipeline.

Automatic devices are placed not only on radiators, but also at the following points:

  1. Safety group of a boiler that is connected to a closed system.
  2. On underfloor heating collectors.
  3. On the pipeline, if it has a high point.
  4. Into a buffer tank and an indirect heater boiler.
  5. On heated towel rail coils.
  6. To the circuit splitter.

In addition, automatic devices must be installed where there are problem areas in heating networks. If the pipeline makes a U-shaped loop, then air accumulates in these places, which must be released using bleeders.

Only automatic releases cut directly into the pipeline, but not manual ones. Mayevsky's tap is not capable of capturing air bubbles, since it does not have a corresponding chamber, so they are designed for installation on heat exchangers.

Knowing where to place automatic air releases, you can check the correct location of these products. If your system has a Mayevsky valve installed on the pipeline, then this placement is incorrect. If the size of the automatic device spoils the design appearance of the radiator and the room as a whole, then you can replace them with special mini-graduates.

Purpose


So, why do you need a hydraulic arrow in a heating system?
The purpose of installing a hydraulic distributor in a heating system is to separate coolant flows, as well as to protect boiler equipment.

Let's consider the main specific situations in which this device can be useful in a heating system:

  1. When it is necessary to create two or more heating circuit circuits with different coolant flow rates. For example, a docked circuit requires more flow than the main one from the boiler. In this case, there are two ways to solve the problem: increase the power and circulation of the main circuit, which will not be economically justified and will lead to a rapid depletion of the equipment’s life. Another way is to install a hydraulic arrow, which will regulate the flow.
  2. In heating schemes that include boilers, heated floors and several circuits, a hydraulic separator will help to avoid the negative impact of these systems on each other. When turning any of the elements on and off, the overall balance of the system will not be disrupted.
  3. If there are several circuits (from one boiler), each of which has its own circulation pump. The hydraulic arrow does not allow them to oppose each other. The devices operate smoothly, the coolant is distributed evenly and in sufficient quantities in all circuits.
  4. There are several boilers that are combined into a single heating circuit. You can’t do this without installing a hydraulic arrow.
  5. Maintainability is another plus that appears when installing a hydraulic distributor. The device makes it possible to maintain the functionality of all circuits, except for the one that needs to be turned off.
  6. In some situations, equipment may be subject to temperature changes. A sudden supply of cold liquid to a heated element of the system can lead to cracks and failure. Cast iron heat exchangers, radiators, etc. are especially sensitive to such changes. This happens when heating is started, during repair work, emergency shutdown, etc.

These are the main functions that the hydraulic gun performs. During operation of the device, sediment accumulates in its lower part from impurities contained in the coolant (scale, rust, sand, and other dirt).

A special tap is installed here to remove sediment, and many attribute this to the additional advantages that the hydraulic distributor provides.

After all, cleaning the liquid from impurities has a beneficial effect on each element of the system and extends their service life.

In addition, the device is equipped with the ability to bleed air dissolved in water. If it accumulates in radiators, it leads to a decrease in heating efficiency. So the hydraulic separator is also an air vent.

In the warranty card for some types of equipment you can read that the manufacturer is responsible and is ready to accept faulty equipment only if there is a hydraulic separator in the system.

The air vent is an invisible worker of the heating system

Any engineering system consists of a large number of parts, assemblies, and equipment. Each element, be it a boiler or a regular air vent, performs its own function, ultimately affecting the overall reliability and durability of the system. We will talk about such a simple device at first glance as an air vent.

Rice. 1. Corrosion of steel pipes

Who will be indifferent to the pieces of dismantled pipelines ( Fig. 1

) or heating devices?
As a rule, this makes an indelible impression on ordinary people, in whose eyes the question freezes: “How did something even work?!” Rice. 2. Mayevsky crane ( R .400)
Fig.
3. Automatic air vent VALTEC VT .502
In addition to those listed, there are also special radiator air vents ( Fig. 4

), also related to automatic ones.
Rice. 4. Radiator automatic air vent V ALTEC VT.501
When installing a heating system, the air vent is installed at the highest point of the system. Often you have to place it right under the ceiling. In standard designs, the spool outlet is located on top of the device ( Fig. 5

), which sometimes makes it difficult to install and maintain in confined spaces.
But this does not apply to the VT.502 air vent ( Fig. 3
). VALTEC pays special attention to adaptation

Rice. 5. Lever air vent design

Unlike standard automatic air vents, VALTEC VT.502 has a more advanced design, due to which the number of parts is reduced and there are no hinged parts. This solution ensures high reliability and extends the service life of the device.

Rice. 6. Design of air vent VT.502

The operating principle of the gas release device of an automatic air vent is somewhat reminiscent of the well-known wheel nipple (car, bicycle). They pressed the spool - air came out, released it - the valve closed. Only in the case of a nipple, excess gas is removed manually, and in the case of an air vent - automatically, due to the mechanical action of a bracket attached to the float. The air-gas environment releases itself.

Rice. 7. Shut-off valve V ALTEC
VT.539
The air vent, like a safety valve or expansion tank, is an important element of system safety, therefore the overall reliability of the heating system depends on the correct selection, installation and subsequent operation.

Hydraulic arrow for heating operating principle, purpose and calculations

A traditional heating system without the use of special components may have certain disadvantages. Its functioning without important modifications and adjustments will become unbalanced. A correctly mounted hydraulic heating arrow helps to remove the imbalance.

It is important to use this unit to reduce the level of thermal fluctuations inside the boiler and create coordinated operation of the circulation pumps

In current conditions, the demand for a hydraulic needle is evident in most heating systems. Functionally, it is a compensation chamber that provides communication between independent heating circuits.

  1. The need for waterworks equipment
  2. What does a hydraulic separator look like?
  3. The principle of operation of a node in the system
  4. Additional functions
  5. Carrying out calculations
  6. Special conditions
  7. How to properly combine a manifold with a hydraulic arrow

Separator device for waste water from continuous blowdown

The separator has a simple device; its body is made in the form of a vertical cylindrical container operating under pressure. Based on the permissible pressure, the bottoms of the housing are made flat or elliptical. The supply of purge water to the tank can have a flattened shape or a round cross-section.


Source of the diagram: cotlomash.ru

The flow of incoming hot water is swirled by supplying it to the wall of the separator tank, thanks to the placement of special guide devices inside. As a rule, the blowing flow rate to the separation device is set to no less than 1% of the steam output of the boiler unit.

At the very bottom there is a drainage fitting for periodically clearing the continuous blowing separator from sludge contaminants. The water level in the tank is maintained automatically by a float-type regulator.

The principle of operation of the hydraulic arrow

Let's look at the operating principle of the hydraulic separator. Since there is nothing inside the pipe of the device, it is clear that the regulation of the coolant is carried out due to physical laws. How it works:

When the equipment is just starting up, the temperature of the coolant is not yet sufficient to somehow heat the room, and the circulation pumps are already dispersing it through the radiators. The water, reaching the hydraulic arrow, is directed downwards and rotates in a small circle and the boiler works for itself, quickly increasing the temperature of the coolant.

Hydraulic processes occurring in a hydraulic arrow

After the balance in the supply and return temperatures is restored, the flows practically do not mix, and the hydraulic arrow only performs the functions of collecting impurities and air from the liquid. But in practice, such an equilibrium is practically unattainable and short-lived, so the presence of a hydraulic arrow will always be justified.

If for some reason the system flow increases, and the ducts in the boiler are smaller in diameter and simply cannot provide a higher flow. Then the water in the hydraulic arrow is mixed (the required volume of liquid is added from the return to the supply) and each element of the system receives as much as it requires - the boiler is smaller, the pipeline branches are larger.

Long-burning heating boilers especially urgently need to install a hydraulic arrow, since they have several combustion modes (from ignition to extinction) and at each stage of operation it is necessary to create stable conditions of pressure and temperature.

Installation recommendations

Requirements for installing a separator in a heating system.

An air and sludge separator is installed in the supply immediately after the boiler. As noted above, the largest number of bubbles are released from water when it is heated in a boiler. If they are not removed immediately, they will dissolve in the cooling water.

The device is installed in front of the circulation pump. This prevents air bubbles from entering the pump housing, which in turn reduces wear on pump parts.

Separators for degassing and sludge removal

Fig.1 Separator

The separators that appeared in recent years in the Russian Federation began to be produced in Europe more than 30 years ago and have become a standard element for degassing and removing sludge from heating and water supply systems. In addition to removing plugs, separators remove microbubbles and sludge particles from the water flow and combine the functions of air vents, filters and deaerators. Separators do not require consumables, energy or maintenance, operate for several decades, and have a simple and reliable design without moving parts.

The universal separator is a metal cylinder with an air vent at the top, a sludge discharge valve at the bottom and a stationary mechanical separating element inside (Fig. 1). An element inside the separator ensures rapid transport of microbubbles to the top and deposition of insoluble particles below as the water flow passes through the separator. The separator's automatic float air vent removes air accumulated at the top, and periodic sludge removal is carried out manually using a ball valve at the bottom of the separator. In both cases, the system does not depressurize. When the system is initially filled with water, large air bubbles are quickly removed using a special valve in the air vent housing. Separators are installed vertically.

Separators from different companies, as a rule, differ in different types of separating elements. In Pneumatex separators (Switzerland), such an element uses a petal spiral (spirals) with a profiled surface made of stainless steel, installed vertically along the axis of the separator (Fig. 1). The mechanisms for extracting gases and solid particles may also be different. As a rule, the gravitational mechanism of particle sedimentation and bubble sublimation is used. To enhance the effect, the flow speed inside the separator is reduced (the cross section is increased), and the flow is laminarized. Some models use a centrifugal effect to spin the flow inside the separator. When using working elements with a large area, the mechanism of sorption of microbubbles on the surface is activated with their further merging into larger bubbles and floating up.

The range of application of separators is quite wide.

For example, Pneumatex industrial separators (standard sizes DN 50 – 600 mm) are capable of processing flows in the range of 5 – 2000 m 3 /h. The housings of industrial separators are made of steel.

Brass separators for small objects (standard sizes DU 20 – 40 mm) process flows up to 5 m 3 /h. All brass separators are assembled from basic elements and can be easily transformed.

Filters in air purifiers

The following types of filters are used in air purifiers:

  1. Pre-cleaning . Conventional mesh filters, which are used at the first stage of cleaning, trap large particles of dust and animal hair.
  2. HEPA filters . They are an accordion assembled on both sides with micro-holes. They cope with mold and fungi spores, animal hair, and dust mites.
  3. Coal . Fights dust and absorbs odors using activated carbon.
  4. Electrostatic (ionic) . They work on the principle of ionization, provide a high degree of purification, and cope with microorganisms.
  5. Photocatalytic . Purify the air using UV radiation. They completely disinfect the room from pathogenic bacteria and carcinogenic substances.

Separators for heating systems

Devices made of anti-corrosion brass and stainless steel;

Quick removal of dirt particles and air pockets;

Options for any engineering systems, including those with high temperatures and pressure;

Various connection options;

Ability to work in an aggressive environment;

Prevents cavitation and corrosion;

The ability to significantly increase the service life of heating, water supply and cooling systems.

Gas/air microbubble separators, sludge separators, gas/air and sludge microbubble separators are divided into three types.

Just a gas/air microbubble separator

– removes
air microbubbles
from the heating system.

Sludge separator

– the smallest particles with a size of 5 microns (=0.005 mm) are separated and removed, but the pressure in the heating system does not drop, even with a large accumulation of dirt.

Separator of microbubbles of gas and sludge - removes both air and contaminant particles.

Separators are manufactured

with different types of connections, usually small diameters with threaded connections, and from 50 mm already with flanges or for welding.

The most advanced separation and deaeration systems for heating systems

developed in Europe, such companies as
Spirovent (Spirovent) Netherlands - Holland and Flamco (Flamco) Netherlands,
are leaders in the production and sales
of separators, non-blocking air vents, automatic make-up systems and deaerators of various
types
for heating systems, hot water supply
and
cooling systems.
A distinctive feature of the products produced is reliability, service throughout Russia, price-quality ratio at the highest level. And the payback of this equipment is guaranteed, even if you don’t notice it!

Heating and hot water supply systems have “invisible enemies”. These are micro-bubbles of air and particles of sludge,

destroying pipes from the inside.
Tracking their appearance is like looking for a needle in a haystack. However, there are special automatic devices for this - gas and sludge separators.

How are separators constructed?

Each gas microbubble separator

has a metal body with a ventilation valve and an eyelet for fastening.
Inside there is an air chamber, a separating drum,
and an outlet device for cleaning or washing.

They operate as follows: the flow, passing through the separator,

slows down.
As a result, air bubbles
rise upward.
They enter the air chamber and from there are discharged outside using a special non-blocking air vent.
Non-blocking air vents are very reliable and durable, because the operation of the gas/air and sludge microbubbles separator itself depends on their operation
.
Sludge separator

It works on a similar principle, only the accumulation of deposits occurs in the lower
part of the separator
and is completely removed when flushed.
Moreover, having a sufficiently large volume, the separator
does not create additional resistance
to the heating
or hot water system, even with a large accumulation of dirt. This is due to its special design.

Advantages:

These devices are made of materials that are resistant to corrosion, mechanical damage and oxidation.

100% tightness is a virtue that all separators

. Buying them means protecting yourself from leaks.

Customers often ask if the separator will become clogged,

if the coolant contains large particles of sludge.
Most modern models do not have this problem. The most successful of them (Spirovent brand separators)
are capable of removing foreign bodies as small as 5 microns and, of course, all large particles!

Separators

does not require maintenance or constant monitoring. Most models operate fully automatically.

These devices can be considered “quick response” devices. They only take a few seconds to remove any air lock or sludge!

Modern separators

work silently.

To start the device, you do not need to slow down the entire system.

Any separator

easy and quick to install and lasts a long time.

Buy a separator

Anyone can get gas - its price is reasonable and affordable for most buyers.

So if air pockets and dirt are frequent guests in your pipeline, we recommend installing gas and sludge separators, deaerators and non-blocking air vents.

Anyone can buy them at the Teplostok store - even if you live in the most remote regions. After all, this is not a reason to endure inconvenience and constantly change pipes!

We are always ready to help you make your choice and organize the supply of separators directly from European factories!

Why do you need an air separator?

A device that can cope with the problem of air locks and other contaminants. Called an air separator. If you do not use this device, air and air pockets in the heating system can cause many problems in the coordinated operation of all elements of the system. First of all, the heat transfer of devices begins to decrease.

The absence of a separator can sooner or later lead to premature wear of pump parts, bearings and blades, which will significantly reduce its efficiency.

If the separator does not work or does not work correctly, the inside surface of radiators, boilers and pipes becomes vulnerable to corrosion. The separator is able to completely remove oxygen from the system, thereby de-airing it. One of the disadvantages of the separator is the creation of resistance to the flow of coolant, which directly has a negative impact on the hydraulics of the heating system.

How does the performance of a heating system without a separator deteriorate?

  • Small bubbles stick to the walls of the radiator, which stops giving off heat. Heating efficiency is reduced to a minimum.
  • The pump that supplies the water wears out, works inefficiently, or stops working altogether.
  • Oxygen entering valves, pipes and filters leads to metal destruction.
  • The consequence of corrosion is the appearance of rust, which moves along with water masses. Rust accumulations form sludge, which causes the heating system to malfunction.

More recently, the fight against the presence of gas in the system happened like this: the system was always kept under some pressure, which made it possible to protect against oxygen suction. To prevent air penetration, special pipes were used. In places where the greatest accumulation of oxygen occurred, air vents were installed.

Do-it-yourself hydraulic arrow for heating


Since the structure of the device is simple, many people want to make it themselves.
Calculations of the size of a hydraulic arrow for heating begin with the diameter of the pipe, which is suitable for a particular system.

For calculations you will need the following data:

  • Boiler power (kW) - W.
  • The difference between the flow and return temperatures is ΔT.

By substituting the data, you can use the formula to calculate the minimum internal diameter (D) in mm.

2-3 internal diameters of the device should “fit” between the nozzles.

But not everything is as simple as it seems. To make an arrow yourself, you need welding skills. The services of a hired specialist will cost quite a bit. It is not always easy to find high-quality pipes with straight threads, then you will have to resort to the services of a turner. As a result, the total cost of materials, labor and time may even exceed the cost of purchasing a ready-made factory device.

There is one more point in which homemade products are inferior to factory-made analogues. Since they do not have a thermal protective casing, the separator radiates heat where it is not intended by the owner.

Modifications

Serial continuous blowing separators in Russia are produced by all boiler plants in accordance with TU 3113-017-00210714 dated 2008. The dimensions of the purge separator tanks range from 300 to 800 mm.

They are capable of accepting a volume of waste water from 0.15 to 0.7 m3 and are used for drum steam and once-through boilers.

The most popular continuous blowing separators are:

  • SNP-0.15, continuous blowing separator DN 300, permissible pressure 0.6 atm., temperature 113 C, flow rate 1.0 t/hour, capacity 0.15 m3;
  • SNP-0.15, diameter 300 mm, permissible pressure 8 atm., temperature 175 C, flow rate 1.0 t/hour, capacity 0.15 m3;
  • SNP-0.15, diameter 300 mm, permissible pressure 14 atm., temperature 194 C, flow rate 1.0 t/hour, capacity 0.15 m3;
  • SP-0.28, diameter 450 mm, permissible pressure 45 atm., temperature 170 C, flow rate 0.7 t/hour, capacity 0.28 m3;
  • SP-0.7, diameter 600 mm, permissible pressure 60 atm., temperature 170 C, flow rate 2.75 t/hour, capacity 0.7 m3.

This modification of the separators at the top of the body has a separating mechanism bolted to the mounting ring. It consists of a set of guide blades bent in a special way, designed for fine separation of microscopic droplets of moisture from steam.

The design has an automatic system for maintaining the level of separated liquid in the working tank. For this purpose, a float regulator is installed in the DN 150 pipe at the bottom of the tank. In order to monitor the level of steam and separated water, a water meter glass with purge valves is installed inside the housing to check their performance.

Blowdown separators have a highly reliable design, are made of high-quality thick-walled metal, and are capable of operating at high temperatures, under high pressure and in a corrosive environment.

Therefore, they have a long service life of at least 20 years and good warranty conditions - three years from the date of shipment to the buyer.

Experts have calculated that it is beneficial to use the heat of the purge water in the separator even with a purge volume of 0.27 kg/s. In the boiler room thermal circuit there are quite a few points where this heat can be used.

For example, it is supplied as a heating fluid to a water-to-water heat exchanger to heat the source water. Dirty sludge water from the separator tank enters another cooler or bubbler, where it gives off heat, lowering its temperature to 45 C, and then exits into the general boiler sewer.

Device

So, what is a hydraulic arrow in a heating system? A hydraulic arrow is a hollow pipe (the cross-section can be round or square) from which pipes emerge. Usually they are located in pairs on opposite sides, but there are options (see “Types of hydraulic separators”).

Materials from which the device is made:

  • Steel (stainless steel or low carbon).
  • Copper.
  • Polypropylene.

Plastic models are suitable for systems from 13 to 35 kW. They are not used in combination with heat generators running on solid fuel, and the temperature in the system should not exceed 70 °C.

Heating system with hydraulic arrow

An automatic air vent is installed at the top point. A drain valve is usually connected to the downward opening to remove dirt. But it is possible to connect an expansion tank to this pipe.

The benefits and harms of an air purifier

Until now, many people are skeptical about this unique invention, trying to understand whether it is harmful to health. So what are home air purifiers, and which one is better to choose?

The principle of operation of the air purifier is the circular circulation of air - from the external environment through the purifier to the outside . The room is cleaned using built-in filters. The home air environment is characterized by the presence of carcinogenic substances (formaldehyde, benzene, nitrogen dioxide), mold, fungi, bacteria and dust impurities.

When the air flow passes through the air purifier, the harmful microparticles it contains are deposited on the filter of the device.

The biggest concern among people is the electrostatic air purifier. It converts oxygen into ozone, which in large quantities is hazardous to human health. However, manufacturers produce devices with low ozone emissions, which is absolutely safe. It should be remembered when choosing an air purifier, benefits and harms are distributed in a ratio of 95 to 5% . In general, air purifiers are not harmful to people.

What is a fan coil unit, operating principle, installation and selection. Installing an air conditioner yourself is not so difficult if you follow our tips.

Clean air in an apartment largely depends on the correct ventilation scheme, read the recommendations at https://klimatlab.com/ventilyaciya/systema/v-chastnom-dome-svoimi-rukami-shema.html

Separators with magnetic traps

Pneumatex separators with magnetic traps (DN 20 – DN 400 mm) trap insoluble iron impurities in water much more effectively than conventional separators. The rod(s) with a powerful magnet are inserted from below from the outside into the separator sleeve and removed before the operation of washing out the sludge without violating the tightness of the system. The magnetic rod is separated from the water by the walls of the sleeve and does not require cleaning or protection from corrosion. The sleeve is made of non-magnetic material, so the magnetic particles quickly settle down and then the sludge is washed away through the valve. For effective flushing, the valve is offset from the center (creating a vortex effect). Separators with magnetic traps also contain conventional separating elements and have all the degassing and non-magnetic particle removal properties of conventional separator models.

Design, purpose and principle of operation of the hydraulic arrow

The hydraulic arrow for heating consists of a bronze or steel body with two pipes for connecting to the boiler circuit (supply pipe + return pipe), as well as several pipes (usually 2) for connecting the heat consumer circuits. An automatic air vent is mounted in the upper part of the hydraulic separator through a ball valve or shut-off valve. at the bottom there is a drainage tap. A special mesh is often installed inside the housing of factory hydraulic arrows, which allows small air bubbles to be directed into the air vent.

Design of the Valtec VT model. VAR 00.

The hydraulic arrow for heating performs the following functions:

  1. Maintaining the hydraulic balance of the system. Turning on/off one of the circuits does not affect the hydraulic characteristics of the remaining circuits;
  2. Ensuring the safety of cast iron boiler heat exchangers. The use of a hydraulic arrow allows you to protect cast iron heat exchangers from sudden temperature changes (for example, during repair work, when the circulation pump is turned off, or when the boiler is turned on for the first time). As is known, a sharp change in coolant temperature negatively affects cast iron heat exchangers;
  3. Air vent. The hydraulic arrow for heating performs the functions of removing air from the heating system. To do this, in the upper part of the device there is a pipe for installing an automatic air vent;
  4. Filling or draining coolant. Most of both factory-made and self-made hydraulic switches are equipped with drain valves, through which it is possible to fill or drain coolant from the system;
  5. Cleaning the system from mechanical contaminants. The low flow rate of the coolant in the hydraulic separator makes it an ideal device for collecting various mechanical contaminants (scale, scale, rust, sand and other sludge). Solid particles circulating through the heating system gradually accumulate in the lower part of the device, after which they can be removed through the drain valve. Some models of hydraulic arrows can be additionally equipped with magnetic catchers that attract metal particles.

Diagram of a heating system using a hydraulic separator.

Advice! It is recommended to install the magnetic trap before the system is filled with coolant; otherwise, when installing the trap, it will be necessary to drain the water from the hydraulic separator.

The process of removing mechanical particles through the drain valve:

  1. Turn off the boiler and circulation pumps;
  2. After the coolant has cooled, shut off the section of the pipeline where the drain valve is located;
  3. We put a hose of a suitable diameter on the drain tap, or, if space allows, we substitute a bucket or any other container;
  4. Open the tap and drain the coolant until clean water comes out without any contaminants;
  5. Close the drain valve, and then open the blocked section of the pipeline;
  6. We subscribe the system and launch the equipment.

Features of choosing air vents

Not everyone knows where to start choosing an automatic air vent. In order for the product to serve for a long time and without failure, it is recommended to buy products of European or domestic production, but not cheap Chinese counterfeits. Buying a cheap automatic graduate can cause the following adverse consequences:

  1. Passing not only air, but also coolant through the valve. In this case, a puddle of water will be detected under the radiators or in the places where the air vents are installed.
  2. The product is jammed, so it will not work.
  3. Rapid deterioration.

Although automatic type safety valves have a shorter service life than manual ones, they must serve without fail for at least 10 years. Manual products have a service life of over 15 years, so instead of buying a cheap machine, it is better to give preference to a manual device. This will allow you to win not only in terms of savings, but there will also be no problems with air bleeding.

To choose good quality Mayevsky uranium, you need to pay attention to the following criteria:

  1. The presence of a handle allows you to conveniently open the valve for bleeding air. The disadvantage of faucets with handles is that they can be accessed by children, who are quite capable of opening them. Installation of such outlets with handles is appropriate only in hard-to-reach places; in other cases, it is recommended to install conventional products with a key or a screwdriver.
  2. To avoid losing the special bleeder key, it should be placed on the wall next to the radiator. This will prevent you from losing the key, and will also allow you to quickly bleed the air.
  3. Buy products with anodized coating. This spraying allows you to protect the metal from the occurrence of oxidative processes.
  4. If your budget allows, you can purchase a product that can trap air bubbles. However, such manual air vents do not differ much in cost from automatic air vents.

In order not to make a mistake with your choice, you need to pay attention to the manufacturer. Depending on the brand of plumbing and heating equipment, not only the quality, but also the cost will differ. In addition, if a closed heating system is used, then you need to pay attention to the technical parameters of the devices, in particular, operating pressure.

Why should you use a hydraulic boom?

Section of the heating system with a hydraulic arrow.

From a different angle.

In heating systems where there are two or more heating circuits (radiators, water-heated baseboards, heated floors, hot water supply), as a rule, the circuits are connected to each other by a common manifold. At the same time, the presence of a common collector can lead to the following problems:

  • The circulation pumps of each circuit influence each other (especially if the pumps differ in power). To overcome the effects of a more powerful pump, the low-power pump must operate at its limit, consuming more electricity than required under “normal” conditions. At the same time, working at the limit of their capabilities, pumps fail earlier. In addition, under such conditions the pump cannot always provide the required performance;
  • Even if the circulation pump of one of the boilers was turned off, its radiators will still heat up (under the influence of the other pumps, coolant circulation in the turned off circuit will continue);
  • Difficulties in calculating pump power for both the boiler and heating circuits. The boiler pump power should be selected taking into account the total power of the heat consumer pumps.

All of the above problems can be solved by a hydraulic arrow.

Side view of the arrow.

Note! In a hydraulic separator, the speed of movement of the coolant decreases sharply (by about 9 times), this is due to the fact that upon entering the separator, the diameter of the flow increases several times (usually 3 times). Thanks to this, pressure drops in the system are eliminated.

What are the dangers of not having air vents?

Air vents are used not only in heating networks of multi-storey buildings, but also in private ones. Each radiator is equipped with an air vent, which is often presented as a manual type.

The air inside the heating system impedes the circulation of the coolant, which negatively affects the heating of the premises. If you do not bleed air from the system in a timely manner, vibration is created when the coolant heats up. This phenomenon can ultimately lead to physical damage to the heating network circuits. The main places of damage are the connection points of heating radiators, as well as welding or soldering seams.

If there is no air in the metal pipe circuit, then the internal walls of the pipelines do not corrode, unlike in cases where there is oxygen in the system. When the internal walls of pipelines rust, not only does the service life decrease, but also the coolant becomes clogged. Draining or bleeding air is a prerequisite, since residents of houses and apartments who ignore to carry out such a procedure themselves may be left without heat.

Where can I buy

Among the domestic enterprises engaged in the production of ready-made hydroshooters is the Novosibirsk company TMK Gulfstream.

Hydraulic distributors are produced here from high-carbon steel with a thickness of 3 mm.

Simple devices with 4 pipes cost from 3.1 thousand rubles. (up to 50 kW). A similar device up to 100 kW will cost almost 4 thousand rubles.

There are models combined with a collector. Such a kit for three circuits will cost 6.8 thousand rubles. Five-circuit – 9.3 thousand rubles. Among the products there is also powerful boiler equipment. For example, a DN100 switch, designed to operate up to 500 kW, will cost 25 thousand rubles.

You can contact the organization by phone +7 913-953-16-80.

Many other manufacturers also produce hydraulic distribution equipment (only the prices are much higher):

  • Italian company Immergas;
  • Ariston;
  • Meibes and others.

Air purifiers for home: top 10

The table shows the most popular models of air purifiers, according to customer reviews.

RatingNameCharacteristics (filters, coverage area)Cost, rub)
1AIC XJ-3800A1HEPA filter, photocatalytic, carbon, ionization. S= 60 m2 16.000
2Daikin MC707VMPre-cleaning, electrostatic, ionization. S = 42 m2 50.000
3Redmond RAC-3704HEPA filter, photocatalytic, carbon, ionization. S = 46 m2 24.000
4AIC KJF-20B06HEPA filter, photocatalytic, carbon, ionization. S = 40 m2 11.000
5Boneco P2261HEPA filter, carbon, ionization. S= 60 m2 2.000
6Bork A800 (AP RIH 9935)HEPA filter, carbon. S = 38 m2 40.000
7Mitsubishi Electric MA-E83H-R1HEPA filter, carbon. S = 63 m2 35.000
8Shivaki SHAP-3010HEPA filter, photocatalytic, carbon, ionization. S = 25 m2 14.500
9Atmos Maxiphotocatalytic, carbon, pre-treatment, ionization. S = 30 m2 14.000
10Philips AC 40144.5HEPA filter, carbon. S = 55 m2 30.000

Air humidifier benefits and harms, how to choose a reliable device. Read our article on how to make a dehumidifier with your own hands.

Which air humidifier is best to choose for a child: tips and tricks here.

Rating
( 2 ratings, average 4 out of 5 )
Did you like the article? Share with friends:
For any suggestions regarding the site: [email protected]
Для любых предложений по сайту: [email protected]