How to set up a gas water heater: adjust gas, water temperature


Preparing to set up a water heater

Although there are instructions for the Bosch, Selena and Neva gas water heaters on how to set them up correctly, not everyone understands how to do this. Having made a mistake at the very beginning, the device begins to work not as it should. You should start by regulating the water supply.

First of all, adjust the water regulation. If you do it at the last moment, then all the settings will be incorrect. The flow must be the smallest. The values ​​can be found in the documentation, they are usually 6, 10 and 12 liters.

The main thing is that there is only one tap for work.

Manufacturer – Germany

JUNKERS (Junkers) BOSCH (Bosch)

BOSCH Neckar JSD20 ⁄ 26 – B23BOSCH Neckar JSD20 ⁄ 26 – B31
Installation and operating instructions for the JUNKERS BOSCH WR gas water heater
10-2B13-2B15-2B10-2G13-2G15-2G10-2P13-2P15-2P
Instructions for installation and operation of the BOSCH Therm geyser
6000 S8000S

VAILLANT

Instructions for installation and operation of the geyser VAILLANT atmoMAG
14-0/0 RXZ14-0/0 RXI14-0/0 GRX
Installation and operation instructions for the VAILLANT MAG geyser
pro 11-0/0 XZC+OE 19/2 XZ-C+remium SOE 19/2-24/2 XIPpremium SOE 19/2-24/2 XIpremium OE 19/2-24/2 XZpremium OE 24/2 RXIpremium OE 24/2 RXZ
Instructions for installation and operation of the geyser VAILLANT GEYSER MAG
275/12 XZ350/12 XZ440/12 XZ

Starting the device and adjusting the temperature

To correctly set up hot water in the device, you must:

  • Open the hot water mixer fully;
  • Using the water switch, select the required temperature value;
  • Close the tap.

According to the advice of professionals:

  • Wait for the moment when the pressure in the line drops, but the column will still work;
  • Turn the water toggle handle to the maximum;
  • Turn the gas regulator to the minimum value until the temperature is as desired.

For final preparation, it is worth adjusting the gas supply. To do this, you need to look at the technical data sheet and find out the minimum value for this brand.

The toggle switch is turned to the minimum value.

Turn on the gas supply valve. At the gas water heater, Electrolux and Ariston do this after connecting to the network. The Oasis, Junkers and Bosch gas water heaters are connected when the batteries are installed.

The hot valve is turned on and the device starts working.

How to adjust the water temperature

Turn on the mixer and check the water heating temperature. It must be twenty-five degrees more than the original one. It is worth noting that the water in a gas boiler heats up gradually. The geyser is adjusted using the gas lever.

Reference! You can also adjust the temperature using the water toggle switch. If the flow force increases, the heating temperature will decrease.

Professionals do not recommend heating water above fifty-five degrees. This has a bad effect on the device, as scale forms.

Blood pressure problems

Setting up a geyser requires some time. Accordingly, the result will be visible later. After each stage, it is worth pouring out the water and letting it heat up again so that the values ​​are correct. Low pressure in the device may interfere with normal operation.

If you have problems with blood pressure, you should perform the following manipulations:

  • Remove the casing from the device;
  • Loosen the locking bolt, use a pressure gauge to check;
  • Remove the seal from the adjusting screw;
  • Turn on the boiler;
  • Set the values ​​to maximum, unscrew the hot water supply taps;
  • Adjust the desired pressure.

The Bosch gas water heater, namely its pressure in the nozzles, is regulated in the following way:

  • Remove the casing;
  • Attach a pressure gauge;
  • Loosen the locking screw;
  • Attach a pressure gauge to check the pressure in the injectors to the nozzle.

Next, the Bosch gas water heater with maximum thermal power is regulated:

  • Remove the seal from the screw;
  • Turn on the device;
  • Hot water taps are turned on;
  • The adjusting screw adjusts the pressure in the nozzles;
  • Put the seal in place.

There are brands that have a special “Winter-Summer” mode with temperature adjustment. This handle was made at the bottom of the Ariston gas water heater. Adjustment of the Oasis gas water heater is located on the front panel. The peculiarity of the mode is that in winter the power is higher than in summer. The heating power of the liquid in the column is directly related to the temperature of the inlet stream. In winter, the regulator is set to “maximum”, the heating will be at its highest. In summer, the temperature of the inlet flow is higher and is set to the minimum position. This saves resources.

It is easy to remove bad pressure when checking.

To do this, you must perform the following manipulations if the device has already been used:

  1. Pay attention to the rubber membrane. The performance of this part is directly related to the pressure in the line. At the moment the integrity of the membrane is broken, namely when it is exhausted, gas does not flow and the burner does not turn on. The problem is solved by replacing the part.
  2. Pay attention to the mesh filter. It is located at the entrance to the water block. The water pressure becomes lower due to debris clogging the part. The problem is solved by cleaning.

Popular models and their technical characteristics

  • Oasis Glass 20VG is a universal boiler for private houses and multi-room apartments. Distinctive features include a bright, attractive design, electric ignition, and a large diameter radiator tube. The column also has an LCD display. Productivity – 10 l/min, at 20 kW of power.
  • Oasis 200G is an ideal solution for operation on liquefied gas from a cylinder in conditions where gas is not supplied to the house. The presence of adjustment elements, several modes and low cost with high efficiency are the distinctive features of this boiler.
  • Oasis TUR 24 - two color schemes will allow the water heater to fit into any design, the unit operates from the mains, has a built-in fan, the boiler operates in automatic mode - the device will turn on when the hot water tap is open.
  • Oasis B-12W is a small water heater with a power of 11 kW and a capacity of 5 liters per minute. The unit is suitable for a country house or a small apartment. The control panel has a display and adjustment toggle switches.

offers the Russian buyer a wide range of boilers for various purposes. You can purchase a water heater running on liquefied gas or electricity, small boilers with low power for a summer residence, or large-sized installations for a large private house with several baths. Before purchasing, you need to calculate how much supplied water is needed in your case, and take a unit with a more powerful performance as a reserve.

Important! Thus, even after a few years, when the power decreases, the boiler will function at a comfortable level

How to adjust the flame of a gas water heater

Another way to set up a gas water heater is to adjust the flame. On the body of semi-automatic and automatic machines there is a handle designed to adjust the gas. With its help, the supply of blue fuel increases and decreases. The power of the device is directly related to this part.

As soon as the flame becomes larger, the gas consumption will be higher and the water will heat up better. Professionals advise changing the gas transmission speed to properly set the burner. As soon as the burning intensity is selected, the knob for changing the water pressure is applied. In order to change the combustion temperature, it is worth changing the “Winter-Summer” mode.

Adjusting the igniter of the gas water heater will help reduce gas costs in semi-automatic machines. The wick is adjusted using the bolt on the pilot burner. You should be careful when making settings. If you reduce the flame of the gas water heater's igniter too much, the device will stop working. If the flame increases excessively, excess gas consumption will occur.

Setting details

These devices have only one geyser temperature regulator. Thanks to it, the heating temperature and power are adjusted. The self-diagnosis system evaluates the operation of the components when turned on. If there are problems, the red light comes on and the device is blocked from starting. Then it is necessary to adjust the water pressure.

Then you need:

  • Remove batteries from the compartment;
  • Turn off the microswitch;
  • Provide a source of electricity;
  • Turn on the hot tap and turn on the microswitch;
  • The pressure on the burner should be maximum;
  • After saving the settings, the orange lamp will turn on.

In other columns, the water temperature is adjusted by turning the toggle switch and controlling the strength of the water flow.

Important! When adjusting, it is prohibited to exceed the maximum temperature specified in the instructions.

Unfortunately, it is impossible to easily set the settings according to the instructions. Each system has different meanings. If you have difficulties setting up the gas water heater temperature regulator with your own hands, you should turn to professionals.

Prevention of scale formation in the heat exchanger

To avoid the hassle of dismantling the heat exchanger and descaling it, you should use the gas water heater correctly.

It is easier to prevent the formation of salt deposits than to get rid of them later.


Any instantaneous water heater requires proper care. Information on servicing a specific model can be found in the instructions that come with the gas water heater.

Preventive measures:

  1. You should swim in water with a temperature of up to +40 °C. This temperature regime is good for health and does not harm the column.
  2. For washing dishes, a temperature of 45-50 °C will be sufficient. The water will be comfortable for your hands and the fat will dissolve well.
  3. Washing can also take place at a temperature of 45-50 °C. For severe contamination, you can add another +5 °C.

The process of formation of solid deposits is accelerated by temperature conditions with intense heating up to +80 °C. Scale begins to be deposited even on the perfectly smooth walls of the heat exchanger, and if there is roughness on the surface, then the fastening becomes “reinforced concrete”.

Poor pressure

Let's look at what affects the water pressure in a gas water heater:

  1. Presence of blockages. Every pipe through which water moves tends to become clogged with debris. If we take an Electrolux geyser as an example, the blockage occurs in the mesh filter filled with lime and rust. If the water flow is low, the pressure will be minimal.
  2. Engineering works. In this case, scale appears inside the heat exchanger. When the water is shut off and the water unit of the gas water heater resumes operation, a “water hammer” occurs, after which some of the scale penetrates into the mixer and forms a blockage.
  3. Device power. For Bosch geysers and other models, the power of the device is important. It will create good pressure in the system. If the power of the device is less than eight, then the pressure will be minimal. For good operation of the geyser water unit, it is worth purchasing a device with a power of eight to ten kilowatts.
  4. Scale. It usually occurs in metal containers in which water is brought to a boil. In a gas water heater, the heat exchanger is considered a tank. With hard water, scale forms on its walls, which subsequently moves into the tubes, due to which the pressure decreases.
  5. Preventive actions. Any device, including a geyser, needs regular maintenance, namely the prevention of blockages. In most cases, a decrease in water pressure occurs due to careless use of the device.

General description of the model range

Italian technologies used in the production of Zanussi gas water heaters are distinguished by their reliability and quality. The body is made of metal, but some models have glass lining. It contains knobs for controlling temperature, power, and a display that displays the set parameters.


Gas water heater from Zanussi

Through the window on the front, the flame on the gas burner is monitored. The Zanussi column is connected to 2 water intake points. But the manufacturer recommends installing on one, it’s more comfortable to use.

All Zanussi water heaters are available with a multi-stage safety system. Working units are equipped with built-in sensors. Zanussi models are activated when the hot water tap is opened. When it closes, the system shuts off the water and gas flow and turns off.

How to solve a problem

If the filter is clogged, you should remove this part from the device. Clean it with a stiff brush and water. If, during cleaning, a violation of the integrity of the filter is noticed, it is worth replacing the part with a similar one.

If the hot water pipe is clogged, you should run cold water in the opposite direction. The plug is removed, a container is placed under the device under water and both taps are turned out. The spout is closed with your finger. It is considered possible that cold water will push the clog forward.

It is not recommended to use chemicals that remove scale from the column. Their composition can easily destroy the metal surface. The best option is to use citric acid, which is dissolved in hot water.

If the blockage has advanced further than the pipes, it can easily penetrate into the faucet. The most “vulnerable” places where blockages mainly appear are considered to be a thin rubber hose, a filter and a faucet. The problem can be solved by disassembling the mixer and performing a thorough inspection. Dirt is removed using running water.

What malfunctions do the Neva Lux dispenser have?

The display of the Neva Lux geyser indicates an error code when problems occur.

Common fault codes that also occur at the Neva Transit gas water heater:

E7. After seven attempts to turn on the device, it goes out or does not work at all. The problem lies in the failure of the electric valves, the accumulation of soot on the electrode, the mixing of the ionization sensor, or the gas block boiling. The solution is to replace faulty parts or clean the soot with a brush.

L0. Insufficient fuel supply.

Causes:

  • Poor water pressure;
  • Decrease in temperature;
  • Exceeding the pressure of the gas water heater Neva Lux.

The problem can be solved by adjusting the temperature, installing a reduction gear and descaling the radiator.

E0. The device turned off on its own. Fuel does not move into the device. The solution is to check the gas valve of the Neva Lux gas water heater. In most cases, the gas supply stopped for some time.

E8. Malfunction related to the traction sensor. It is usually associated with a clogged chimney or a broken sensor. The solution is to clean the chimney from soot yourself or with the help of utility services, or replace the sensor with a new one, as well as check the tightness of its contacts.

Do-it-yourself troubleshooting

Even with proper installation and proper care of water heating equipment, the owner of a gas burner may encounter some malfunctions, which most often arise after long-term operation of the unit.

Fault typeProbable CausesPossibility and solution
Failure to turn on the unit in the presence of a spark dischargeGas supply valve is closedCheck the shut-off valves, open the gas valve if necessary
Insufficient water pressure inside the plumbing systemIncrease the water pressure in the system using accessible methods
Clogged filter systemClean the filters
Formation of a significant amount of scale in the heat exchangerCleaning the heat exchanger from scale accumulations
No spark discharge in the unitThe water supply regulator is closed or there is no water pressure necessary for the regulator to operateSet the regulator to the extreme right position
Presence of a weak spark dischargeViolation of contact connections within the electrical circuitUsing a tester, find the problem and fix it
Presence of discharged or low-power batteries in the compartmentReplace batteries with working ones
Turning off the geyser after working for a short timeTriggering of the draft sensor caused by a lack of draft in the chimney systemClean the chimney and restore sufficient draft
Gaps in areas from the gas outlet pipe to the connecting pipesPerform sealing using heat-resistant self-adhesive materials or special sealants
Triggering of the water overheating protection sensorReduce the amount of gas entering the water heating unit
At maximum heating mode, insufficiently hot water enters the water supply systemAccumulation of soot on the fin part of the heat exchanger or the formation of a large amount of scale in the heat exchanger pipes.Thoroughly clean the heat exchanger inside and outside
The gas pressure level inside the gas supply system is too lowContact gas service specialists
The weak flame of the burner is represented by elongated, smoky and yellow tonguesSignificant dusting of internal surfaces in the gas burnerPerform a complete cleaning of the main burner
Lack of temperature data on the indicatorBroken contacts in the hot water supply temperature sensor circuitIdentify and eliminate the malfunction, which may be represented by terminal disconnection or oxidation
Failure of the indicator device for determining the temperature regimeReplace the temperature indicator
There is no spark discharge and no boiler activation if the batteries are in good conditionLack of rod mobility or souring souringAfter dismantling the microswitch, release the stationary part of the rod
Broken microswitch, control unit or solenoid valveIdentify and replace all faulty elements
Electrical circuit failure in the area from the control unit to the microswitchCheck the connector contacts inside the control unit, check the microswitch wires

The activities of the company, representing gas water heaters under the Oasis brand, are based on absolute financial transparency and complete loyalty regarding relationships between clients and partners, taking into account the accumulated unique experience. It is thanks to these features of activity that Oasis water heating equipment becomes more popular every year.

Source

Other device problems

In addition to error codes, there are other malfunctions that are also typical for the Neva Transit gas water heater:

  1. The appliance is too noisy. In this case, you should start turning the water regulator and reduce the pressure.
  2. The gaskets “stick out” in the pipe connection areas. The problem is solved by replacing the element.
  3. The display has stopped working. The problem lies in faulty contacts, a broken display and a faulty temperature sensor. The solution is to replace the parts and the display itself.
  4. The device stopped lighting up. This problem is also typical for the Zanussi gas water heater. The malfunction lies in membrane stretching, overheating and a broken device element. Solved by replacing the part with a new one.

When repairing with your own hands, it will take a long time to study the repair material and actually set up the gas water heater. The result the first time may not be the same as in the repair instructions in the literature and may even be disastrous. The best option would be to entrust the matter to professionals.

Parameter table

The Zanussi range of instantaneous water heaters is represented by 5 models. They differ slightly in parameters, so for convenience they are discussed in a comparative table.

All speakers are equipped with electronic ignition, small in size, and mounted on the wall. Power up to 24 kW, capable of heating up to 12 l/min. The model range is presented in white, but options with a glass coating and a pattern are possible.

Rating
( 1 rating, average 4 out of 5 )
Did you like the article? Share with friends:
For any suggestions regarding the site: [email protected]
Для любых предложений по сайту: [email protected]