The work of the Kiturami concern is aimed at the production of heating devices using biofuel and gas. But it was the diesel fuel equipment that ensured the popularity of this manufacturer.
Advantages of diesel fuel installations:
- Ease of use thanks to the ability to control any function using the remote control. The thermostat built into it determines the operating and temperature conditions of the coolant. The operation of the boiler does not depend on the size of the chimney and the presence of draft, since the existing turbocharging effect contributes to the forced direction of exhaust gases into the chimney;
- High efficiency is achieved due to the aerodynamic flow during fuel combustion;
- Possibility of self-configuration;
- Year-round hot water supply;
- Availability of a self-diagnosis system with information about the operation and malfunctions of the system;
- Acceptable price;
- Variety of model range.
The only negative is the type of fuel, which creates a negative environmental situation when burned.
Kiturami diesel boiler design
Model overview
KSG 100
Heating capacity 116 kW. Two circuits - heats the house and heats the water. Closed chamber. Radiator made of steel. The kit includes a control unit, a remote thermostat, instructions that contain error codes and troubleshooting, a connection diagram, etc. Capable of heating a room of 4600 sq. m. Turbocyclone burner type, characterized by minimal emissions of nitrogen oxides. The compact model easily fits into modern interiors. Compared to conventional boilers of similar power, it weighs approximately 40% less and volume is 65% less. easy to transport. Efficient operation of the heat exchanger guarantees high combustion temperatures. Innovative chimney pipe - made according to the Kiturami patent, it is 3% more efficient than models from other manufacturers. There is self-diagnosis and three modes - sleep, water heating, absence.
KSG 70
Powerful floor-standing unit with 81.4 kW. It works to heat the room and heat hot water. Heats rooms up to 650 sq. m. Chimney type - open combustion chamber. The maximum coolant temperature is 85 °C. 92% efficiency. Dimensions 128x58x89 cm.
World 5000
Wall installation. 2 circuits. They heat rooms of 400 sq. m and heat water for domestic needs without additional equipment. Maximum hot water flow 14.6 l/min. Models World-5000 13R-35R are allowed to be used on the territory of the Russian Federation - they have permission from Gostekhnadzor. There is a self-diagnosis function. Leakage protection.
World 3000 30R
Wall-mounted convection type appliance. 34.9 kW. Will heat an area of 350 sq.m. Efficiency 93%. Closed chamber. Volatile. There is auto-ignition and flame modulation.
Hi Fin 20
Mounted installation. Closed chamber. Maximum heating output 23.3 kW. Designed for heating rooms up to 230 sq. m. 85.9% efficiency. Economical gas consumption. Stainless steel radiator. Innovative burner design - there is internal and external combustion. Thanks to the interaction of the process with electronic ventilation, combustion stability is maintained regardless of weather conditions. To achieve minimum fuel consumption, fuel consumption is adjusted. There is an expansion tank and a circulation pump.
Kiturami chimney components
- Coaxial chimneys Kiturami FF 75/100/1000, FF 75/100/1300, FF 75/100/1500
are designed for gas wall-mounted boilers; they differ in the length of the coaxial pipe - 100, 130 and 150 cm, respectively. - The coaxial chimney Kiturami FF 80/100/1300
is designed for gas and diesel floor-standing boilers, the connecting diameter is 80 mm, it is available in only one length - 130 cm, in most cases it is necessary to purchase an additional vertical exhaust pipe extension and an extended corrugation for air supply. - Single-pipe chimney FE 80/1300
is designed for Kiturami TURBO diesel boilers, connecting diameter 80 mm. - Chimney extensions, 500 and mm,
are available in diameters of 75 and 80 mm and are designed for extension in vertical or horizontal directions. - S-shaped transition
- designed for installation of coaxial chimneys into the wall on which the gas boiler hangs; they are produced only with a diameter of 75 mm.
IMPORTANT! Installation of equipment can be done independently, but it is better to entrust such important work to professionals.8 (495) 256 00
What are consumers saying?
South Korean products are becoming increasingly in demand on the domestic market, and this is not happening by chance. As noted by everyone who already has Kiturami diesel boilers in operation, reviews from owners say that the main advantage of diesel equipment is its special design.
Modern models of heat exchangers are made of high-alloy steel, which significantly exceeds its analogues in durability. Making the boiler circuit out of copper allows it to interact well with water or antifreeze. Thanks to this feature, the device has increased thermal conductivity.
Diesel heating boilers kKiturami have positive reviews, they note the presence of an electronic system with internal and external remote controls, which simplifies the process of controlling the boiler and allows you to monitor its operation from anywhere in the boiler room.
KituramiTurbo HiFiN 13 26 958.00
The design features of KSG gas boilers include a heat exchanger with two circuits made of high-strength steel, a turbocyclone burner with electric ignition, an electronic system control unit and a thermostat regulator. Before starting the equipment, the tank is initially filled with diesel fuel, which must sit for at least half an hour.
Specifications
The operational characteristics, dimensions and parameters of Turbo series boilers are presented in the table below. It is clearly seen that the series of floor-standing diesel boilers covers a power range from 10 to 35 kW, which is quite enough to heat houses up to 250-275 square meters. Part of the heat will be used to prepare hot water, which must be taken into account in the calculations.
All Kuturami double-circuit boilers and heat exchangers, by the way, are ideally designed specifically for these tasks.
Boiler model | Unit change | TURBO-9R | TURBO-13R | TURBO-17R | TURBO-21R | TURBO-30R |
Power | kcal/hour | 9000 | 13000 | 17000 | 21000 | 30000 |
Power | kW | 10,5 | 15,1 | 19,8 | 24,4 | 34,9 |
Fuel consumption | liter/hour | 1,13÷1,5 | 1,6÷1,97 | 1,87÷2,15 | 2,28÷2,80 | 3,75÷4,30 |
Efficiency | % | 92 | 92 | 92.2 | 92.4 | 91.8 |
DHW consumption | Δt=25ºC | 6,0 | 9,7 | 11,3 | 14,0 | 23,3 |
Δt=40ºC | 3,8 | 6,1 | 7,1 | 8,7 | 14,6 | |
Heating supply and return | mm | 25 | 25 | 25 | 25 | 25 |
Hot water inlet/outlet | mm | 15 | 15 | 15 | 15 | 15 |
Chimney diameter | mm | 80 | ||||
Power supply | V/Hz | 220/50(60) | ||||
Energy consumption | W | 80 | 160 | |||
External size | w×d×h | 325×600×835 | 365×650×930 | |||
Weight | kg | 60 | 79 | 85 | 85 | 85 |
Fuel consumption
Fuel consumption is indicated in the table with technical requirements. However, please remember that actual consumption depends on individual settings. Based on the actual power required to heat the house, an appropriate nozzle is selected from the set offered by the manufacturer.
Thermal power, fuel consumption and fuel combustion mode are set. The parameter indicated in the table displays factory presets sufficient to ensure proper performance provided that only high-quality fuel is used, more often this means diesel fuel with winter additives that do not allow it to thicken or separate paraffin in excess of the norm.
In a real situation, for a boiler model with a power of up to 15 kW, you can expect fuel consumption at the level of 8 liters per day, taking into account the frequency of burner operation and the optimal temperature regime in the house. However, this is not the limit.
The right approach to choosing a heating mode, as well as installing a controller with variable temperature conditions, for example, depending on the time of day and day of the week, can reduce consumption even more.
Chimney
Cuturami boilers, gas, diesel, floor-mounted or wall-mounted, are mostly equipped with a closed combustion chamber and, accordingly, a forced exhaust gas removal system. The Turbo series we are currently reviewing is no exception.
Chimney installation diagram
The chimney for boilers is coaxial to simultaneously supply fresh air from the street and remove exhaust gases. Since the exhaust temperature after passing through the heat exchangers is no longer high, the requirements for the heat resistance of the chimney are reduced, and the list of acceptable materials is expanded.
In the best case, a steel coaxial chimney is still used, but a ceramic vertical chimney with a group of internal separate channels for supplying air, removing gases from the combustion chamber and ventilating the boiler room can be effectively used in the same capacity.
The size of the chimney is strictly indicated in the boiler specification and operating instructions. For the entire Turbo series it is 80 mm.
If desired, you can make a chimney with a slightly larger diameter, but no more than 50% above the specified value, that is, up to 120 mm.
Under no circumstances should the size and cross-section be reduced. Even though the removal of combustion products is forced, the resistance of the chimney will greatly affect the combustion mode and the quality of fuel combustion.
turbo 13r
The boiler model number corresponds to the amount of heat generated per hour - 13,000 kcal/hour.
Converted to conventional kilowatts, the resulting value is 15.1 kW. The declared power is enough to heat a house with an area of up to 150 m2. Naturally, one should take into account the heat costs for preparing hot water. If a significant consumption of hot water is predicted, and regularly, then the thermal power for the heating circuit will naturally be lower.
Reliability and balanced operation, combined with the affordable cost of the boiler, gives a clear advantage in the case of using several boilers simultaneously in one building, for example, when dividing the heating circuit for each floor separately or when covering a large area in two more directions.
Advantages and disadvantages of Kiturami boilers
The products of the South Korean concern Kiturami are different:
- high quality;
- modern design;
- functionality;
- reasonable prices.
security sensors
The Turbo series includes diesel floor heating boilers that cope with two tasks at once, namely, heating the room and heating water for household needs. At the same time, owners will not need to purchase the necessary equipment
, because this device has a boiler-type system. The undoubted advantages include a high level of protection, which is achieved by working:
- sensors;
- control panel;
- thermostat;
- exhaust gas removal systems.
The advantage of all Kiturami equipment is its durability under various operating conditions. This quality is especially pleasant for domestic consumers. Since the Kiturami company has many dealerships, it is not difficult to obtain failed parts of the Kiturami diesel boiler.
Kiturami diesel boilers have a number of advantages over similar products from other manufacturers. In terms of diesel fuel consumption, these devices have high efficiency indicators
— per minute, at average productivity, the device creates 20 liters of hot water.
But the biggest achievement of the Kiturami company is the market of relatively low prices. A kiturami diesel boiler will cost 20–30 thousand rubles. In addition, the range of diesel equipment is quite wide, due to which the demand for it is high both among private home owners and industrialists.
The Kiturami single-circuit diesel boiler is the heating equipment of a South Chinese concern that has been producing similar equipment for half a century. The company continuously improves its models and also guarantees users their high quality. The manufacturer's boilers operating on liquid fuel have repeatedly received prizes, awards and diplomas for reliability and safety.
The equipment is manufactured in two types: Turbo and KSO. Turbo series units are used for domestic needs. They are classified according to the amount of heat generated. KSO series boilers have a design similar to gas appliances. However, when replacing burners and electronic equipment, they can operate using other types of fuel. These boiler models are equipped with a turbocyclone burner, which ensures high efficiency since the fuel is completely burned in them. Diesel boilers "Kiturami" are distinguished by their simplicity of design, so they are convenient to operate and maintain. The units are easy to install and come with a remote control panel. In addition, the price of these heating devices is quite affordable.
Features of Kiturami boilers:
- High quality.
- Functionality.
- Light weight.
- Compact sizes.
- Strength and durability.
- Attractive design.
Kiturami single-circuit diesel boilers are equipped with only one water heating circuit, consisting of one to three heat exchangers, each of which is filled with water and heats it. Such boilers can also provide a household with hot water, but with an indirect heating boiler. For double-circuit boiler models, installation of such a boiler is not required.
Presentation of Kiturami products:
Even at the stage of designing heating in a house, you have to operate with the general technical characteristics of the boiler, but in the end you still need to go to the store and choose a very specific model from the huge assortment on the market.
It will be useful to find out in more detail what a Kiturami diesel boiler is, what models are in the line, and how they can be better than other offers on the market.
Owner reviews
“In 2012, a Kiturami 17R boiler was purchased. Great purchase. He was supposed to work as a backup for the Evan Epo-18 electric boiler, which acts as the main one in the heating system. Since an area of 150 square meters was heated. m, then the choice specifically fell on equipment with increased power. In severe frosts, the main boiler cannot cope with maintaining the required temperature conditions and stops working due to a drop in voltage in the network. Kiturami acts as a lifeguard, heating and providing water.” Tambov, Arkady “The Kiturami Turbo boiler is of interest for hot water due to the presence of a SHOWER function, which is capable of producing a small volume of hot water in a short period of time.” Sochi, Marina “Wonderful equipment. No matter how many such systems have been installed, practically no one has any complaints. All of Siberia is heated by them.” Ekaterinburg, Sergey “The cost of this equipment alone can attract interest. Spare parts are always available, the remote controls are unified.” Moscow, Konstantin “We have our own complaints about the boilers of this company. In my opinion they are not entirely reliable. So we had to resort to repairs twice. Automation can’t handle it.” St. Petersburg, Alexander
Benefits of Kiturami
Korean boilers, being many times more expensive than their domestic counterparts, enjoy well-deserved respect. Consumers are attracted by their reliability and thoughtful design, which frees the user from the usual troubles associated with the operation of gas equipment. Pros:
- All manufactured modifications have two circuits. A double-circuit boiler provides not only heating, but also hot water supply to the entire house. Domestic analogues have a drawback - when you turn on the water, its temperature quickly decreases. The Koreans have solved this problem - when the tap opens, the automation rebuilds the operation of the system - the water heating mode replaces the heating mode.
- Operation at different temperatures is possible thanks to two independent circulation rings. When the consumer turns off the water, the reverse transition occurs - to heating or waiting.
- Simple controls. Even a child can master it. The user's task is to select and set the temperature. For heating separately, for water – separately. Then the automation does everything without human intervention.
- A gas detection system is provided - if a leak occurs, a shutdown occurs, the flame goes out, and an accident is excluded.
- Energy saving modes. Many Kiturami modifications are equipped with a room thermostat-controller, which allows you to select modes - “absence”, “sleep”, “shower”.
- In winter, when it is frosty outside, the “Koreans” automatically maintain a stable temperature - freezing of the heating system is excluded. If the owner is away for a long time, it is not necessary to turn off the device - just set the “absence” mode.
- The equipment diagnoses problems independently, displaying the appropriate code on the screen. This function allows the user to easily identify and fix the malfunction - the instructions decipher the codes and indicate what to do.
Features of Kiturami diesel boilers
A distinctive feature of Kiturami devices is electronic control. The boiler has a remote control, with which the user can conveniently interact with the device from a distance.
Device
The design of the Kiturami boiler is a combination of external and internal elements.
External parts:
- frame;
- Control block;
- pipes for connecting hot water supply and heating systems;
- chimney hole.
The control unit is responsible for the operation of the boiler. It helps you select parameters and modes. If necessary, the device starts protective functions and self-diagnosis.
Internal elements:
- DHW heat exchanger;
- turbocyclone liquid fuel burner;
- sensors;
- the combustion chamber;
- heat exchange device of the heating system.
Principle of operation
The boiler operates on diesel fuel as follows. The pump pumps the required amount of diesel fuel from the tank into the burner device. The fuel is heated and supplied to the combustion chamber through the nozzle simultaneously with air. The electrodes ignite the mixture, forming a stable torch in the firebox.
Combustion products move through heat exchange channels, heating the water. Exhaust gases are released under pressure into the chimney using a turbulator. The noise level is reduced thanks to the use of special inserts in the smoke channel.
Specifications
The efficiency indicators of Kiturami equipment are superior in many respects to diesel boilers from other manufacturers. A wide range of model parameters allows you to choose the ideal option for both home and industrial enterprise.
General characteristics:
- Efficiency 84–93%;
- service life - 10 years;
- power range 10.5–465.1 kW;
- DHW capacity - from 6 to 100 l/min;
- fuel consumption: 1.5–55.8 kg/hour;
- the cost of devices is from 26,800 to 511,099 rubles.
Fuel consumption
The use of a turbocyclone burner (a Kiturami proprietary invention) allows for efficient use of fuel. The special metal insert heats up to 800 °C, almost completely burning diesel fuel.
Thanks to this type of burner, fuel consumption is 1–1.5 liters to produce 10 kW of heat.
Advantages
Korean-made diesel boilers are distinguished by a successful combination of manufacturability and low cost.
Other advantages:
- Environmentally friendly. The patented burner design burns fuel completely, reducing emissions.
- Efficiency. Three-pass heat exchanger promotes maximum heat transfer.
- Electronic control. Using the display and remote control, the user configures the operation of the equipment to suit his needs.
- Energy saving. Switching operating modes helps save fuel resources.
- Safety. The equipment is equipped with flame, temperature, fuel and water level sensors in the system, as well as frost protection.
- High efficiency. Amounts to 84–91%.
- Versatility. Easy transition to gas by replacing the burner.
- Long service life. They can work uninterruptedly for up to 10 years.
- Modest dimensions. Placement requires 1 sq. m. area.
- Self-diagnosis. In case of malfunctions, information about the state of the system is displayed.
More details about the benefits of the Kiturami boiler delivery kit can be seen in this video.
Flaws
All the disadvantages of liquid fuel boilers are related to the type of fuel used.
Main disadvantages:
- the need to place the boiler room in a separate room;
- high noise level of liquid fuel burners;
- unpleasant smell from diesel fuel;
- the need to install containers with a supply of diesel fuel;
- dependence on the power grid;
- rapid increase in the cost of diesel fuel.
Solid fuel
Solid fuel boilers are suitable for use in rural areas. To obtain thermal energy, the units consume biofuel: wood and coal. It is possible to use briquetted and granular materials of various origins.
Features of operation:
- availability of fuel material;
- limited time on one tab;
- the need to constantly manually service the boiler: load new portions of fuel and clean out the ash several times a day;
- the chimney and pipe periodically become clogged with soot deposits.
Solid fuel boilers come in classic and pyrolysis types. In the first case, the unit has one combustion chamber.
The second option is structurally more complicated. The firebox of such a device is divided into two parts. Fuel is placed in the upper chamber and heated until pyrolysis occurs. The wood gas generated in the process is forced through a nozzle into the lower chamber and burned there.
Pyrolysis boilers are more efficient. Another advantage is their low waste.
Kiturami KF
The series is represented by the KF-35 model with a power of 24 kW. A pyrolysis type boiler is capable of heating rooms up to 240 square meters. m. One full load of fuel allows continuous operation of the unit throughout the day. The heating rate of domestic water is 14.7 l/min. Efficiency - 91.5%.
Design advantages:
- spacious loading chamber for 50 kg;
- stainless heat exchanger;
- a ceramic nozzle between combustion zones 1 and 2 promotes complete combustion of fuel and pyrolysis gases;
- large loading hatch;
- the boost fan maintains a stable fireplace in the firebox;
- the secondary combustion chamber is equipped with a device for removing pyrolytic liquid;
- Ash receptacle in the form of a box.
Kiturami KRP
The KRP line includes pellet boilers that use granulated wood waste. Granule diameter: 6–8 mm, length: 1–3 cm. A full hopper allows the equipment to work without interruption for up to 5 days. The model range consists of 2 sizes: 20A and 50A.
Technical features:
- automatic fuel supply via a screw mechanism;
- built-in expansion tank and circulation pump;
- ash pan in the form of a box;
- pellet burner in the shape of a bowl with an increased ignition area;
- automatic vibration cleaning of grates.
Specifications
The Kiturami company was founded in 1962 and began its activities with the production of solid fuel boilers. Gradually increasing production capacity, closely monitoring global market trends and using innovative developments from its own research and development department, the company has become one of the largest manufacturers of heating equipment. Korean devices fully meet stringent international standards, have an ISO-9001 quality certificate and are subject to serious control at all stages of production. Kiturami gas boilers are a complex design of interconnected components and assemblies, the main one of which is a heating element made in the form of a turbocyclone burner. All models are equipped with a system for forced removal of combustion products, which ensures maximum safety for people present in the room and eliminates the risk of exhaust gas entering the room.
Both liquefied and natural gas can be used as fuel for Kiturami boilers. Kiturami boilers are available in a double-circuit version. They provide independent heating of water in two systems - heating and domestic hot water. And if in Russian-made boilers, when heating and hot water are turned on at the same time, the temperature of the coolant drops slightly, then on Korean models, when the hot water supply is turned on, the system automatically switches to heating mode. Thanks to this design feature, the temperature of the water in the network remains stable, moreover, it becomes possible to operate in different temperature conditions for heating and hot water circuits.
The choice of gas boiler power depends on the area of the room that it will heat. Household models with a power of 15.1–34.9 kW are capable of efficiently heating a room with an area of 120 to 340 m², and are the most preferred option for owners of country houses and city apartments. More serious devices have a maximum power of 465 kW. Thanks to the possibility of cascade connection, which can number up to 10 devices, they can easily cope with a huge space of 46,500 m². Such boilers are successfully used for heating shopping centers, warehouses and industrial workshops.
Kiturami devices are characterized by a high speed of water heating: the average productivity of most units is about 33 liters of hot water per minute. This is a very good indicator and allows Korean models to compete on equal terms with well-known Czech and German brands. All heating devices are equipped with a multifunctional room thermostat, which automatically monitors the room temperature and, if necessary, starts or turns off the boiler. Models can easily switch from gas to diesel fuel, which makes them more versatile and significantly expands their scope of application. Korean boilers are equipped with a device status warning system and instantly notify the owner of a problem. In the event of a breakdown, a digital code instantly appears on the display screen, indicating which unit has failed or is not working correctly.
For ease of troubleshooting, there are the following generally accepted error codes:
- 01–03 – the system does not detect fire, which is why the ignition is automatically blocked and the device turns off;
- 04 – temperature sensor failure; in this case, the boiler must be turned off and a specialist must be called immediately;
- 05 – opening of the overheating sensor or activation of the seismic sensor;
- 06 – the boiler has stopped recognizing the blower speed;
- 07 – the fan does not work correctly, which may be due to the accumulation of condensation in the elbow or wind that penetrates the chimney; Before calling a specialist, you should exclude the above reasons and eliminate extraneous influences on the device.
The lineup
View: tile listing table
Type: | liquid fuel, classic |
Fuel: | diesel |
Number of circuits: | double-circuit |
Power: | 15.1 kW |
Dimensions: | 360x920x650 mm |
Weight: | 64 kg |
Price: 30,000 rub.
Type: | liquid fuel, classic |
Fuel: | diesel |
Number of circuits: | double-circuit |
Power: | 19.8 kW |
Dimensions: | 360x920x650 mm |
Weight: | 72 kg |
Price: 31,700 rub.
Type: | liquid fuel, classic |
Fuel: | diesel |
Number of circuits: | double-circuit |
Power: | 16.8 kW |
Dimensions: | 325x700x602 mm |
Weight: | 40 kg |
Price: 32,000 rub.
Type: | liquid fuel, classic |
Fuel: | diesel |
Number of circuits: | double-circuit |
Power: | 15.1 kW |
Dimensions: | 325x700x602 mm |
Weight: | 30 kg |
Price: 32,400 rub.
Type: | liquid fuel, classic |
Fuel: | diesel |
Number of circuits: | double-circuit |
Power: | 19.8 kW |
Dimensions: | 325x700x602 mm |
Weight: | 40 kg |
Price: 33,900 rub.
Type: | liquid fuel, classic |
Fuel: | diesel |
Number of circuits: | double-circuit |
Power: | 19.8 kW |
Dimensions: | 325x700x602 mm |
Weight: | 30 kg |
Price: 35,000 rub.
Type: | liquid fuel, classic |
Fuel: | diesel |
Number of circuits: | double-circuit |
Power: | 24.4 kW |
Dimensions: | 325x700x602 mm |
Weight: | 32 kg |
Price: 39,400 rub.
Type: | liquid fuel, classic |
Fuel: | diesel |
Number of circuits: | double-circuit |
Power: | 24.4 kW |
Dimensions: | 360x920x650 mm |
Weight: | 75 kg |
Price: 40,100 rub.
Type: | liquid fuel, classic |
Fuel: | diesel |
Number of circuits: | double-circuit |
Power: | 34.9 kW |
Dimensions: | 360x920x650 mm |
Weight: | 82 kg |
Price: 41,000 rub.
Type: | liquid fuel, classic |
Fuel: | diesel |
Number of circuits: | double-circuit |
Power: | 24.4 kW |
Dimensions: | 325x700x602 mm |
Weight: | 41 kg |
Price: 42,200 rub.
Type: | liquid fuel, classic |
Fuel: | diesel |
Number of circuits: | double-circuit |
Power: | 29.1 kW |
Dimensions: | 365x930x650 mm |
Weight: | 80 kg |
Price: 43,000 rub.
Type: | liquid fuel, classic |
Fuel: | diesel |
Number of circuits: | double-circuit |
Power: | 34.9 kW |
Dimensions: | 365x930x650 mm |
Weight: | 80 kg |
Price: 44,700 rub.
Type: | liquid fuel, classic |
Fuel: | diesel |
Number of circuits: | double-circuit |
Power: | 29.1 kW |
Dimensions: | 365x930x650 mm |
Weight: | 48 kg |
Price: 45,300 rub.
Type: | liquid fuel, classic |
Fuel: | diesel |
Number of circuits: | double-circuit |
Power: | 34.9 kW |
Dimensions: | 365x930x650 mm |
Weight: | 48 kg |
Price: 52,500 rub.
Operating rules
The user controls the Kiturami boiler via a thermostat. Settings are made using knobs and buttons. Information about the current state of the unit is displayed by indicators on the display and lights.
Main functions:
- Room. The main mode that is used when people are in the house. To activate, press the “Presence” button and set the desired temperature using the regulator.
- Dream. Helps save fuel while on vacation. To switch, press the “Sleep” button and set the required temperature. The settings will remain in effect for five and a half hours. Then the “Indoor” mode will be restored.
- Bath. Allows you to use a large amount of hot water for two and a half hours. After the expiration date, the device switches to the previous activated mode.
- Absence from the premises. Used to prevent the heating system from freezing when the user is away. It assumes fuel savings by reducing the temperature to the minimum permissible.
- Timer. Allows you to program the boiler operating time and shutdown.
For long and uninterrupted operation of the equipment, you must strictly follow the rules of its use.
Operating rules:
- Do not store combustible or flammable objects and substances near the device;
- have a fire extinguisher in the boiler room;
- Do not repair or disassemble the unit yourself;
- prevent freezing of water in the heating system;
- carry out maintenance 1–2 times a year;
- clean the chimney and chimney of soot several times a year;
- When dirty, drain the sediment from the fuel tank and change the filter.
Blitz tips
Diesel single-circuit and double-circuit models have been developed, the latter are more convenient, but more expensive
If you choose the first option, you will need to purchase a boiler and other appliances and accessories, but its cost will still be lower.
It is worth paying attention to the depth of the fuel intake according to the criterion for determining the deep location of the fuel and fuel tank. According to fire safety, fuel tanks must be buried in the ground to an appropriate depth
At low power, the intake depth is higher.
The cost of installing the equipment will include the price of the heater, its installation, startup and commissioning work, maintenance and spare parts for its repair.
Features of Kiturami boilers
Kiturami is a South Korean company with more than half a century of experience in the development and production of heating boilers and related equipment.
During this time, the company became one of the leaders in the domestic Korean market, and also found a large sales market in North America and nearby Asian countries. In our country, Kiturami boilers have been officially distributed for at least ten years and have already managed to show their good side.
The main emphasis in promoting boilers is on the introduction of innovative technologies and, in particular, our own developments, which have no analogues from other manufacturers or determine the narrow specificity of the equipment’s operation.
Diesel boilers, by definition, are not considered as the main model range for a wide range of applications. In terms of economic feasibility, they are inferior to gas, electric and even solid-state boilers. However, they are still in demand among consumers due to a number of reasons why liquid fuel is becoming preferable.
In remote areas of residence, where there is no stable connection to power grids and no gas supply, the issue of fuel availability becomes acute. At the same time, the heating of the house must, by definition, work uninterruptedly throughout the entire season. If for many countries such situations are rather the exception to the rule, then for us, on the contrary, they are commonplace, the reason for which is the vast expanses that separate populated areas.
Diesel fuel, unlike gas, is easier to transport and easier to store with minimal risks to life and the environment. Unlike solid fuel boilers, diesel fuel, when burned, provides uniform heating and a greater degree of control over resource consumption. And finally, the design of a diesel boiler and, in particular, the burner does not limit the use of other heat sources.
With minimal changes, a diesel burner can be replaced to use blue fuel, and boilers equipped with an extensive combustion chamber and grate can quickly switch to using coal, wood or pellets.
Kiturami diesel boilers are highly technologically advanced and are ideally balanced equipment for using diesel fuel as a heat source, and at the same time they are excellent for the listed types of conversion to operate on gas or solid fuel. So constructive and functional flexibility is the first significant advantage.
Kiturami boilers often use their own developments and a unique layout. On the one hand, this reduces the maintainability of heating equipment, but on the other hand, it ensures the highest boiler efficiency and balanced operation while observing simple and transparent operating rules
This is the second good reason to turn your attention to diesel boilers originating from South Korea.
The last advantage is the cost of boiler equipment. Even taking into account the high performance and proven quality of the boilers, their cost does not exceed the market average among similar offers.
So it turns out that Kiturami boilers have three features: a balanced design, high efficiency and an affordable price.
Kiturami boiler design
Price range
Gas boilers Kiturami Twin Alpha will cost the buyer an amount in the range of 25-35 thousand rubles, depending on the power of the unit.
This is the average price in Russia; in remote regions it may be increased due to the complexity of delivery or other logistics problems. The boilers are sold in a basic configuration; the usual delivery package includes only the unit itself, packaging, a set of mounting hooks and instructions.
Therefore, when purchasing, you must immediately order the desired type of chimney, as well as purchase a voltage stabilizer and water filters
This is important, since Kiturami Twin Alpha boilers are demanding on the power supply condition
If the voltage supply is unstable, the control board fails, the price of which is about 10-13 thousand rubles.
Excessively hard water is also contraindicated, since it damages the internal pipelines of the boiler.
You should not skimp on warranty service. Some users only increase their expenses, thinking that waiving the warranty will allow them to save money.
Installation nuances and requirements
The installation of a Kiturami diesel appliance must be carried out by qualified specialists with special permission. The equipment is located in a separate non-residential premises. The boiler room must be well ventilated.
Burner settings and efficiency
The Kiturami diesel burner is adjusted before putting the device into operation or when performing maintenance. The adjustment is made by moving the air damper screw until the flame reaches the desired shade.
The efficiency of the burner is determined by the color of the flame:
- black and red - it is necessary to increase the air supply;
- bright white - signals the need to close the damper;
- yellow-red - is optimal, in this case the burner operation is considered effective.
The flame should be even. If the torch deviates to the side, it indicates the need to replace the nozzle.
Boiler piping
Connecting the Kiturami boiler to utility networks must be carried out in accordance with the instructions.
The harness includes connection to:
- heating system;
- DHW circuit;
- chimney and pipe;
- electrical networks;
- fuel line.
When connecting to heating and water supply pipes, shut-off valves and filters are installed. To compensate for the expansion of the coolant, special tanks are used. In systems with forced circulation, pumps are installed.
For the operation of Kiturami diesel heat generators, it is necessary to connect to a 220 V network. The device is provided with a separate socket located at a distance of at least 30 cm. If there are voltage drops, it is recommended to install a network stabilizer. Grounding is carried out to a depth of at least 30 cm.
To remove flue gases, a special set of forced exhaust pipes is used. The horizontal section of the chimney is placed at an angle of 5 degrees to prevent precipitation and condensation from getting inside.
The device is connected via a fuel line to a container with diesel fuel. Using a pump, fuel is pumped into the system, passing through the fuel filter, and supplied to the burner.
Settings
It is better to entrust the initial startup and setup of Kiturami boilers to a specialist who can correctly determine the optimal operating mode, select the desired type of nozzle and check the fuel consumption depending on its characteristics and even the method of connection and location of the fuel tank.
For self-installation, detailed instructions are included with the boiler, according to which you can determine the operating mode closest to the design value.
The main thing is to adhere to the sequence of actions defined in the technical documentation and visual aids for putting the equipment into operation.
Setting up and adjusting the boiler settings should be carried out not only at the first start-up, but also during maintenance before each new season and to switch to summer mode, in which only the DHW circuit will be used.